Objective: To evaluate in vitro the bond strength of resin cements in high-translucency zirconia restorations as a function of the light-curing system and the type of resin cement. Methods: Forty-eight third molars received high-translucency zirconia (KatanaTM – Kota – Tokyo, Japan) and were randomly distributed into four groups (n=12) according to the light-curing system (indirect with commercial equipment or direct with the new optical fiber illuxminator) and resin cement type (light- or dual-cured). The optical fiber device conducts LED light to hard-to-reach areas. A micro shear bond strength test applied a 50 Kgf load at 0.5 mm/min until failure. Two-way ANOVA and Tukey’s test (5% significance) analyzed results. Results: The highest bond strength occurred in the direct optical fiber system with dual-cure cement (p<0.05), also increasing bond strength for light-cured cement. Conclusion: Within the limitations of this laboratory study, the use of the optical fiber illumination system was associated with higher bond strength values of resin cements to high-translucency zirconia compared with the conventional system, depending on the type of cement used. These findings indicate that the device may favor adhesion in situations with limited light access; however, further studies are required to establish its clinical relevance.