Key result
A folded cascode bulk driven operational transconductance amplifier achieved lower power consumption (620nW) compared to a two-stage OTA (77.26uW) in a 0.18um CMOS process.
The paper presents a comparative analysis of two OTA topologies for biomedical applications operating at 1V in 0.18um CMOS process.
May suit ultra-low-power biomedical sensors; leaves open in vivo validation before clinical use.
This paper presence a comparative analysis of two stage and folded cascode bulk driven operational trans conductance amplifier (OTA) topologies for biomedical applications are presented. A two stage bulk driven OTA and Folded cascoded OTA operated with a 1Vpower supply. Bulkdriven PMOS-transistors as an input differential opamp provides high input common-mode range (CMR). To achieve low power consumption all transistors must be operated in sub threshold region. The test results are carried out in standard gpdk180nm CMOS technologies
No takes yet. Share an insight, caveat, or question.
A 2019 study studied this question. Folded cascode bulk driven OTA vs. Two stage bulk driven OTA was evaluated. A folded cascode bulk driven operational transconductance amplifier achieved lower power consumption (620nW) compared to a two-stage OTA (77.26uW) in a 0.18um CMOS process.