Key result
Two-hour hs-TnT <4 ng/L rules out PET-CT myocardial ischaemia with 100% negative predictive value.
Why the study?
The performance of highly sensitive troponin T assay to detect myocardial ischaemia in low-risk patients admitted with chest pain has been poorly documented.
Does highly sensitive cardiac troponin T assay detect myocardial ischaemia at PET-CT in low-risk patients admitted with chest pain?
Observational (n=48)
Physicians were blinded to hs-TnT results
No
Does highly sensitive cardiac troponin T assay detect myocardial ischaemia at PET-CT in low-risk patients admitted with chest pain?
In low-risk patients with chest pain, an hs-TnT level <4 ng/L provides excellent negative predictive value for excluding myocardial ischemia on PET-CT.
Answers are grounded in this paper and cite their sources.
hs-TnT <4 ng/L showed high NPV for excluding PET-CT ischaemia in low-risk chest pain; leaves open validation in larger cohorts before clinical adoption.
BACKGROUND: Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented. PURPOSE: To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain. METHODS: Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography. RESULTS: Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively. CONCLUSIONS: Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT01374607.
No takes yet. Share an insight, caveat, or question.
Morawiec et al. (2017) conducted an observational in Acute coronary syndrome (low-risk) (n=48). Highly sensitive cardiac troponin T (hs-TnT) assay vs. Standard cardiac troponin was evaluated on Area under the curve for predicting significant ischaemia at PET-CT using hs-TnT at 2 hours (T2) (AUC 0.812, 95% CI 0.616 to 1.000). In low-risk patients with chest pain, an hs-TnT cut-off value of <4 ng/L at 2 hours demonstrated a 100% negative predictive value to exclude myocardial ischaemia at PET-CT.
Synapse has enriched 10 related papers. Consider them for comparative context: