Key result
Acute afterload elevation with an anti-G suit reduces LV peak longitudinal strain and worsens diastolic uncoupling.
Why the study?
Chronic changes in LV hemodynamics mediate changes in LV function, but the acute impact of increased afterload on the LV longitudinal strain-volume relationship and age differences are unclear.
Does acute manipulation of afterload via an anti-gravity suit alter the LV longitudinal strain-volume loop, and do these effects differ between healthy young and older men?
Does acute manipulation of afterload via an anti-gravity suit alter the LV longitudinal strain-volume loop, and do these effects differ between healthy young and older men?
p-value: p=<0.05
Acute increases in afterload immediately alter the diastolic phase of the LV longitudinal strain-volume loop similarly in young and older men, demonstrating its potential for assessing dynamic cardiac function in vivo.
Strain-volume loops may detect acute afterload changes with age differences; leaves open clinical validation in patients.
Chronic changes in left ventricular (LV) hemodynamics, such as those induced by increased afterload (i.e., hypertension), mediate changes in LV function. This study examined the proof of concept that 1) the LV longitudinal strain (ε)-volume loop is sensitive to detecting an acute increase in afterload, and 2) these effects differ between healthy young versus older men. Thirty-five healthy male volunteers were recruited, including 19 young (24 ± 2 yr) and 16 older participants (67 ± 5 yr). Tests were performed before, during, and after 10-min recovery from acute manipulation of afterload. Real-time hemodynamic data were obtained and LV longitudinal ε-volume loops were calculated from four-chamber images using two-dimensional echocardiography. Inflation of the anti-gravity (anti-G) suit resulted in an immediate increase in heart rate, blood pressure, and systemic vascular resistance and a decrease in stroke volume (all P < 0.05). This was accompanied by a decrease in LV peak ε, slower slope of the ε-volume relationship during early diastole, and an increase in uncoupling (i.e., compared with systole; little change in ε per volume decline during early diastole and large changes in ε per volume decline during late diastole) (all P < 0.05). All values returned to baseline levels after recovery (all P > 0.05). Manipulation of cardiac hemodynamics caused comparable effects in young versus older men (all P > 0.05). Acute increases in afterload immediately change the diastolic phase of the LV longitudinal ε-volume loop in young and older men. This supports the potency of the LV longitudinal ε-volume loop to provide novel insights into dynamic cardiac function in humans in vivo.
No takes yet. Share an insight, caveat, or question.
Hulshof et al. (2020) studied Healthy (n=35). Anti-G suit inflation vs. Baseline (uninflated) was evaluated on Left ventricular longitudinal strain-volume loop characteristics (peak strain and diastolic uncoupling) (p=<0.05). Acute inflation of an anti-G suit to increase afterload significantly decreased left ventricular peak longitudinal strain and increased diastolic uncoupling in both young and older healthy men.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: