Key result
Echocardiographic super-response to CRT linked to ~22% lower risk of major heart failure events.
Why the study?
The individual benefit from cardiac resynchronisation therapy varies largely among patients, and different definitions of echocardiographic super-response need comparison for predicting adverse events.
Do different definitions of echocardiographic super-response to CRT predict the incidence of adverse events in patients with CRT implantation?
Cohort (n=110)
No
Do different definitions of echocardiographic super-response to CRT predict the incidence of adverse events in patients with CRT implantation?
Answers are grounded in this paper and cite their sources.
Echocardiographic super-response to CRT strongly predicts favorable clinical outcomes, though these patients remain at risk for ventricular arrhythmias requiring ICD therapy.
BACKGROUND: The individual benefit from cardiac resynchronisation therapy (CRT) varies largely among patients. AIMS: To compare different definitions of echocardiographic super-response to CRT regarding their ability to predict the incidence of adverse events. METHODS: Three definitions of super-response to CRT were evaluated in 110 consecutive patients with CRT implantation: (1) an absolute increase in ejection fraction of ≥ 10%; (2) a decrease in left ventricular end-systolic volume of ≥ 30%; and (3) a decrease in left ventricular end-diastolic volume of ≥ 20%. The primary endpoint was a combination of time to death, heart transplantation, ventricular assist device implantation and hospitalisation for heart failure. Secondary endpoints included time to first appropriate implantable cardioverter defibrillator (ICD) discharge during follow-up. RESULTS: All three definitions of super-response were highly predictive of a reduced risk for reaching the primary combined endpoint (3-year estimators: 64% ± 7% vs 82% ± 7% for ejection fraction ≥ 10%; 63% ± 8% vs 92% ± 5% for end-systolic volume ≥ 30%; and 62% ± 8% vs 94% ± 4% for end-diastolic volume ≥ 20%; all p<0.001). In all three analyses, super-responders had a significantly shorter time from diagnosis of heart failure until the time point of CRT implantation. However, even super-responders, independent of the definition, did experience appropriate ICD discharges during follow-up. CONCLUSIONS: All three definitions of super-response are highly predictive for a favourable outcome after CRT. However, even patients with pronounced reverse left ventricular remodelling experience appropriate ICD discharges during follow-up.
No takes yet. Share an insight, caveat, or question.
Steffel et al. (2011) conducted a cohort in Heart failure (n=110). Echocardiographic super-response to CRT vs. Non-super-response was evaluated on Combination of time to death, heart transplantation, ventricular assist device implantation and hospitalisation for heart failure (p=<0.001). Echocardiographic super-response to CRT (e.g., absolute increase in ejection fraction ≥10%) was associated with a reduced risk of the primary composite endpoint (64% vs 82%; p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: