Key result
Fast-implantable Intuity aortic valve shows feasible concomitant use with mitral prosthesis in early experience.
Why the study?
Concomitant aortic and mitral valve procedures pose challenges due to potential interference between valve prostheses at the mitroaortic junction, and the safety of the fast-implantable aortic valve system in this setting remains controversial.
Can a fast-implantable aortic valve system be safely placed next to a biological mitral valve or rigid mitral ring without interference in patients requiring concomitant procedures?
Case Report (n=2)
Can a fast-implantable aortic valve system be safely placed next to a biological mitral valve or rigid mitral ring without interference in patients requiring concomitant procedures?
The Intuity fast-implantable aortic valve can be safely used during concomitant mitral valve replacement or repair without structural interference at the mitroaortic junction.
Answers are grounded in this paper and cite their sources.
Supports feasibility in select concomitant cases; leaves open need for prospective data before practice change.
Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.
No takes yet. Share an insight, caveat, or question.
Ferrari et al. (2014) conducted a case report in Concomitant aortic and mitral valve disease (n=2). Fast-implantable aortic valve system (Intuity valve) was evaluated. A fast-implantable aortic valve (Intuity) was successfully implanted alongside a bioprosthetic mitral valve or rigid mitral ring in two cases without significant interference.