Key result
Coroflex Blue cobalt-chromium stent shows a 5.5% 6-month target-lesion revascularization rate in real-world practice.
Why the study?
The development of cobalt-chromium bare-metal stents with thinner struts has led to better deliverability and lower target-lesion revascularization rates compared with stainless steel BMS, but clinical efficacy and safety of the Coroflex Blue stent in real-world practice needed evaluation.
Observational (n=2,315)
Yes
The Coroflex Blue cobalt-chromium bare-metal stent demonstrated high procedural success and low 6-month target-lesion revascularization rates in a real-world registry.
Thin-strut cobalt-chromium BMS yielded low TLR in complex real-world lesions; leaves open whether it challenges routine DES use pending randomized trials.
OBJECTIVES: The aim of this registry was to evaluate the clinical efficacy and safety of the Coroflex Blue cobalt-chromium stent in real-world practice. BACKGROUND: The development of cobalt-chromium bare-metal stents (BMS) with thinner struts has lead to better deliverability and lower target-lesion revascularization rates compared with stainless steel BMS. METHODS: The Coroflex Blue Registry was an international, prospective, multicenter registry enrolling patients with symptomatic ischemic heart disease attributable to single de novo or restenotic nonstented lesions of a single vessel amenable for percutaneous stenting. The primary end point was clinically driven target-lesion revascularisation (TLR) 6 months after enrolment, secondary endpoints were technical/procedural success, in-hospital outcome, definite stent thrombosis and major adverse cardiac events (death, myocardial infarction, or TLR) after 6 months. RESULTS: The registry included 2,315 patients (mean age 64.3 +/- 11.1 years, 19.8% diabetes, 37.3% acute myocardial infarction). Although a complex lesion cohort with 60.3% Typ B(2)/C-lesions, the technical success rate was 99.1% and the procedural success rate 98.5%. The incidence of TLR after 6 months was 5.5% and the cumulative 6-month acute/subacute stent thrombosis rate was 1.6%. After 6 months cumulative event-free survival was 90.8% in all patients and 87% in patients with acute PCI for acute myocardial infarction. CONCLUSIONS: This registry demonstrates the safety and efficacy of the Coroflex Blue cobalt-chromium stent platform in real-world practice. In the era of drug-eluting stents (DES), these results raise the serious question if the use of DES for primary prevention of restenosis and TLR is really justified.
No takes yet. Share an insight, caveat, or question.
Bocksch et al. (2009) conducted an observational in Symptomatic ischemic heart disease (n=2,315). Coroflex Blue cobalt-chromium stent was evaluated on Clinically driven target-lesion revascularisation (TLR) 6 months after enrolment. The Coroflex Blue cobalt-chromium stent demonstrated a 5.5% incidence of clinically driven target-lesion revascularization at 6 months in real-world practice.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: