Key result
Standing positions and beam projections during interventional procedures can vary the effective dose to anaesthetists by more than a factor of 10 and the eye lens dose by more than a factor of 200.
Why the study?
How do standing positions and beam projections influence the effective dose and eye lens dose of anaesthetists during interventional procedures?
How do standing positions and beam projections influence the effective dose and eye lens dose of anaesthetists during interventional procedures?
Anaesthetists can significantly reduce their radiation exposure during interventional procedures by optimizing their standing position and being aware of high-exposure beam projections like the left lateral projection.
Position optimization may lower anaesthetist exposure; leaves open prospective validation of clinical impact.
More and more anaesthetists are getting involved in interventional radiology procedures and so it is important to know the radiation dose and to optimise protection for anaesthetists. In this study, based on Monte Carlo simulations and field measurements, both the whole-body doses and eye lens dose of anaesthetists were studied. The results showed that the radiation exposure to anaesthetists not only depends on their workload, but also largely varies with their standing positions and beam projections during interventional procedures. The simulation results showed that the effective dose to anaesthetists may vary with their standing positions and beam projections to more than a factor of 10, and the eye lens dose may vary with the standing positions and beam projections to more than a factor of 200. In general, a close position to the bed and the left lateral (LLAT) beam projection will bring a high exposure to anaesthetists. Good correlations between the eye lens dose and the doses at the neck, chest and waist over the apron were observed from the field measurements. The results indicate that adequate arrangements of anaesthesia device or other monitoring equipment in the fluoroscopy rooms are useful measures to reduce the radiation exposure to anaesthetists, and anaesthetists should be aware that they will receive the highest doses under left lateral beam projection.
No takes yet. Share an insight, caveat, or question.
Kong et al. (2014) studied Radiation exposure in interventional radiology procedures. Standing positions and beam projections was evaluated on Effective dose and eye lens dose. Standing positions and beam projections during interventional procedures can vary the effective dose to anaesthetists by more than a factor of 10 and the eye lens dose by more than a factor of 200.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: