Key result
Ultra-thin Supraflex SES yields a ~7% 3-year MACE rate in real-world CAD patients.
Why the study?
The long-term safety and efficacy of drug-eluting stents remain conflicting due to late restenosis and stent thrombosis after implantation.
Observational (n=237)
No
The use of biodegradable polymer-coated ultra-thin sirolimus-eluting stents in real-world CAD patients demonstrated sustained safety with a low 3-year MACE rate of 6.5%.
Observational 3-year data support safety of ultra-thin biodegradable SES; leaves open randomized confirmation versus contemporary DES.
Introduction: Although drug-eluting stents (DES) have outclassed the use of bare metal stents, the safety and efficacy of DES at long-term follow-up has still been conflicting because of increased occurrence of late or very late restenosis and stent thrombosis after DES implantation. Hence, the present study was aimed to evaluate the 3-year safety and clinical performance of biodegradable polymer-coated ultra-thin (60 μm) sirolimus-eluting stent (SES) in real-world patients with coronary artery disease (CAD). Materials and Methods: This was a physician-initiated, retrospective, single-centre, observational study that included 237 consecutive patients who had previously undergone implantation of only Supraflex SES (Sahajanand Medical Technologies Pvt Ltd, Surat, India) for the treatment of CAD. Follow-up was received after 1 year and 3 years of stent implantation. The primary endpoint was major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and target lesion revascularisation (TLR). Stent thrombosis was considered as a safety endpoint. Results: The mean age of patients was 64.1 ± 10.2 years, and 192 (81.0%) patients were male. The average stent length and diameter were 24.4 ± 9.0 mm and 3.1 ± 0.4 mm, respectively. The cumulative MACE rate at 3 years follow-up was 6.5% which included 4 (1.8%) cardiac deaths, 6 (2.8%) MI, and 4 (1.8%) TLR. There were 2 (0.9%) cases of stent thrombosis. Conclusion: Treatment of patients with CAD in real-world clinical practice was associated with sustained clinical safety and low rates of restenosis, stent thrombosis and MACE up to 3 years after Supraflex SES implantation.
No takes yet. Share an insight, caveat, or question.
Chandwani et al. (2019) conducted an observational in Coronary artery disease (n=237). Supraflex sirolimus-eluting stent was evaluated on Major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction, and target lesion revascularisation. Implantation of the biodegradable polymer-coated ultra-thin Supraflex sirolimus-eluting stent in real-world patients with coronary artery disease resulted in a cumulative major adverse cardiac event rate of 6.5% at 3 years.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: