Why the study?
There were limited data on the outcomes of Indian patients treated with drug-eluting stents of Indian origin.
Supraflex sirolimus-eluting stents demonstrated an 11% MACCE rate at 1 year in a real-world Indian cohort, with outcomes strongly correlated with baseline comorbidities like diabetes and kidney dysfunction.
Initial data on Indian-origin SES; leaves open need for RCTs before practice change.
Background: The introduction of Sirolimus Eluting Coronary Stents (SES) was a major breakthrough in interventional cardiology. The large, randomized, clinical trials using SES have shown a remarkable reduction in angiographic restenosis and target vessel revascularization (TVR) compared with bare-metal stents as well as other drug-eluting stents (DESs). However, there is only limited data on the outcome of Indian patients treated by DES of Indian origin. The purpose of the study was to evaluate the outcomes of the supraflex sirolimus-eluting coronary stents for the treatment of coronary artery disease and to determine major adverse cardiovascular and cerebrovascular events (MACCE). Materials and Methods: This was a single-centre, observational, nonrandomized study that enrolled unselected real-world patients at a tertiary care center who had undergone implantation with supraflex sirolimus-eluting stents. The primary end-point of the study was MACCE, which is a conglomeration of cardiac death, target lesion revascularization (TLR), TVR, cerebrovascular accident (CVA), and heart failure at 1-year follow-up. Results: A total of 100 patients were intervened successfully with sirolimus-eluting stents. Out of total patients, diabetes and hypertension were observed in 38% and 35% of patients. According to ACC/AHA classification, there were 68% Type B lesions and 32% Type C lesions. At 1-year follow-up, MACE was found to be 11%, which is a composite of 4% TLR, 3% TVR, 1% CVA, and 5% heart failure. Diabetes ( P = 0.02), hypertension ( P = 0.01), kidney dysfunction ( P = 0.002), and LV function ( P = 0.01) strongly correlate with outcome (MACCE). Conclusion: There was an acceptable rate of adverse events after implantation of the supraflex sirolimus-eluting stents, although it was slightly higher compared to other studies. Diabetes, hypertension, kidney dysfunction, and LV function strongly correlate with outcome (MACCE).
No takes yet. Share an insight, caveat, or question.
Singh et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: