Key result
Machine learning cardiotocography score linked to ~23-fold higher odds of fetal distress.
Why the study?
Interpretation of fetal heart rate monitoring during the antepartum period is complex, subjective, and has low reliability, motivating development of a machine learning classification model.
Does a machine learning model accurately classify fetal cardiotocography results as normal or abnormal in high-risk pregnancies?
Observational (n=1,472)
Yes
Does a machine learning model accurately classify fetal cardiotocography results as normal or abnormal in high-risk pregnancies?
Odds Ratio: 23.09
p-value: p=<0.001
A machine learning model can classify fetal cardiotocography results with good precision and its abnormality score is significantly associated with adverse clinical outcomes like fetal distress.
May support ML-assisted fetal CTG review in high-risk pregnancies; leaves open prospective outcome trials before clinical adoption.
Purpose: Fetal well-being is usually assessed via fetal heart rate (FHR) monitoring during the antepartum period.However, the interpretation of FHR is a complex and subjective process with low reliability.This study developed a machine learning model that can classify fetal cardiotocography results as normal or abnormal.Materials and Methods: In total, 17492 fetal cardiotocography results were obtained from Ajou University Hospital and 100 fetal cardiotocography results from Czech Technical University and University Hospital in Brno.Board-certified physicians then reviewed the fetal cardiotocography results and labeled 1456 of them as gold-standard; these results were used to train and validate the model.The remaining results were used to validate the clinical effectiveness of the model with the actual outcome. Results:In a test dataset, our model achieved an area under the receiver operating characteristic curve (AUROC) of 0.89 and area under the precision-recall curve (AUPRC) of 0.73 in an internal validation dataset.An average AUROC of 0.73 and average AUPRC of 0.40 were achieved in the external validation dataset.Fetus abnormality score, as calculated from the continuous fetal cardiotocography results, was significantly associated with actual clinical outcomes [intrauterine growth restriction: odds ratio, 3.626 (p=0.031);Apgar score 1 min: odds ratio, 9.523 (p<0.001),Apgar score 5 min: odds ratio, 11.49 (p=0.001), and fetal distress: odds ratio, 23.09 (p<0.001)].Conclusion: The machine learning model developed in this study showed precision in classifying FHR signals.This suggests that the model can be applied to medical devices as a screening tool for monitoring fetal status.
No takes yet. Share an insight, caveat, or question.
Park et al. (2022) conducted an observational in High-risk pregnancy (n=1,472). Machine learning-derived fetus abnormality score vs. Normal score / Reference was evaluated on Fetal distress (association with abnormal probability score in multiple sampling) (OR 23.09, p=<0.001). A machine learning model for classifying fetal cardiotocography results achieved an AUROC of 0.89, and its abnormality score was significantly associated with actual fetal distress (OR 23.09).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: