Key result
Breast implants are linked to ~31% higher odds of coronary angiography despite lower subsequent PCI.
Why the study?
Breast implants interfere with myocardial perfusion imaging and echocardiographic windows, potentially increasing false positive cardiac test results and subsequent coronary angiography.
Does the presence of breast implants increase the rate of abnormal cardiac functional studies and subsequent coronary angiography in adult women?
Observational (n=1,871,335)
Yes
Does the presence of breast implants increase the rate of abnormal cardiac functional studies and subsequent coronary angiography in adult women?
Breast implants are associated with higher rates of false-positive cardiac functional studies and subsequent coronary angiography, despite a lower actual prevalence of coronary disease requiring PCI.
Answers are grounded in this paper and cite their sources.
May prompt unnecessary angiography via false-positive testing in women with implants; leaves open mechanisms and clinical impact pending prospective data.
Background Breast implants interfere with myocardial perfusion imaging (SPECT) and echocardiographic windows leading to increased false positive results. To validate this concept, we hypothesized that patients with breast implants should have higher positive cardiac testing and coronary angiogram with lower percutaneous coronary intervention (PCI) rates compared to women without a breast implant. Methods Using ICD 10 codes for breast implants, abnormal results of cardiac functional study, coronary angiogram, and percutaneous coronary interventions, we evaluated any association between these parameters in adult women with breast implants utilizing the National Inpatient Sample (NIS) database. Results A total of 45,015 women had abnormal cardiac functional studies. A total of 1,871,335 women 18 or older underwent coronary angiography and 865,020 of them underwent PCI. Women with breast implants were 10 years younger with abnormal cardiac functional tests (55.06 vs 65.06 years, p < 0.001). Furthermore, the breast implant cohort had a higher abnormal cardiac functional study which was significant after adjusting for age and comorbidities (OR1.4, CI 0.89-2/28, p = 0.02). Adult women with breast implants had also a significantly higher rate of coronary angiography after age and multivariate adjustment (OR: 1.3, CI: 1.18–1.46, P < 0.001) but a lower rate of PCI (35.7% vs 46.2%, P < 0.001, unadjusted OR: 0.65, CI 0.54–0.78, adjusted OR 0.78, CI 0.65–0.95, P = 0.01). Conclusions Women with breast implants had higher adjusted positive cardiac functional studies, higher rates of coronary angiography, and lower rates of PCI consistent with our hypothesis that breast implant interference can increase abnormal cardiac testing leading to an increase in the utilization of coronary angiography.
No takes yet. Share an insight, caveat, or question.
Movahed et al. (2023) conducted an observational in Suspected coronary artery disease (n=1,871,335). Breast implant vs. Women without breast implants was evaluated on Coronary angiography utilization (OR 1.31, 95% CI 1.18-1.46, p=<0.001). Breast implants in adult women were associated with a higher adjusted odds of undergoing coronary angiography despite a lower rate of subsequent percutaneous coronary intervention.