Key result
Transcutaneous Doppler detects abnormal carotid flow in 100% of HSS patients vs. other heart diseases.
Why the study?
The clinical evaluation of hypertrophic subaortic stenosis lacks a validated noninvasive method to detect its distinct flow pattern in the carotid artery.
Does a transcutaneous Doppler velocity probe accurately identify hypertrophic subaortic stenosis by detecting abnormal phasic carotid artery flow?
Cross-Sectional (n=106)
Does a transcutaneous Doppler velocity probe accurately identify hypertrophic subaortic stenosis by detecting abnormal phasic carotid artery flow?
Transcutaneous Doppler velocity recording of phasic carotid flow is a valid clinical tool for evaluating hypertrophic subaortic stenosis, identifying abnormal flow patterns even when characteristic pulse contours are absent.
Answers are grounded in this paper and cite their sources.
Carotid Doppler may aid noninvasive detection of hypertrophic subaortic stenosis; leaves open prospective validation of diagnostic utility.
A transcutaneous Doppler velocity probe was used to record phasic carotid artery flow in 12 patients with hypertrophic subaortic stenosis. In contrast to the normal Doppler flow pattern of a single large orthograde systolic wave, all patients demonstrated a distinctively abnormal flow profile. A sharp wave of rapid, early systolic flow was followed by an abrupt decrease of flow in midsystole with a slower phase of late systolic flow. In 4 of the 12 patients the distinctively abnormal Doppler flow pattern was found in the absence of the characteristic sharp percussion and low tidal wave carotid pulse contour often present in hypertrophic subaortic stenosis. The Doppler recording of phasic carotid flow seems valid for the clinical evaluation of this disease, since the abnormal abrupt decrease in midsystolic flow was not found in the study of 94 patients presenting with other cardiovascular disease.
No takes yet. Share an insight, caveat, or question.
Claude R. Joyner (1971) conducted a cross-sectional in Hypertrophic subaortic stenosis (n=106). Transcutaneous Doppler velocity probe vs. Patients with other cardiovascular disease was evaluated on Abnormal abrupt decrease in midsystolic flow. A transcutaneous Doppler velocity probe detected an abnormal carotid flow profile in 100% of patients with hypertrophic subaortic stenosis, compared to 0% of 94 patients with other cardiac diseases.
Synapse has enriched 10 related papers. Consider them for comparative context: