Answers are grounded in this paper and cite their sources.
Arguing against the Proposition is Keith Faulkner Ph.D. Dr. Faulkner is the Regional Director of Quality Assurance for the breast and cervical cancer screening programs for the North East, Yorkshire and Humber Government Office Regions of the UK. After graduation from Imperial College, London, he trained as a medical physicist at the University of London. He is a Fellow of the Institute of Physics and Engineering in Medicine (IPEM), the Institute of Physics, and the Society of Radiation Protection (SRP) in the United Kingdom. He maintains an active interest in research in radiation protection, and is the coordinator of the European Commission's SENTINEL project. He is the author of over 250 peer-reviewed papers. His awards include the Founders’ Prizes of the IPEM and the SRP, and the Barclay Prize and Medal of the British Institute of Radiology. With appropriate training of users and relevant quality control, it is possible to generate images with the same or lower radiation dose with digital imaging compared with conventional film/screen systems for general radiography.1 In addition, image quality and diagnostic information (after post-processing) can be improved with digital techniques.2–4 Transmission of images by networks and easy archiving are other fundamental advantages of digital imaging. Networks and digital systems also enable the auditing of patient doses and comparison with reference values in real time.5 With film/screen systems, errors in radiographic techniques or problems with film processors require repeat exposures whereas, with digital imaging, the inherent wide dynamic range and post-processing capability make most retakes unnecessary. Furthermore, if previous films are not available, additional exposures may be required. Hence the use of film/screen systems should be phased out within the next few years because they are unnecessarily hazardous and less versatile than digital imaging. Digital radiology can have additional benefits for developing countries. Digital imaging can be less expensive than film/screen techniques. Compared with film processors, the use and maintenance of digital phosphor plates (computed radiology) and personal computers (PCs) is easier. Even if initial funding to install sophisticated networks and image archiving systems is not available in developing countries, users can use PCs to burn CD-ROMs that are cheaper than radiographic films and more easily transported by patients to other hospitals, if necessary. With film/screen systems, patient doses at the individual level are not so high as to be considered hazardous. However, if we take into account the collective dose for a medium sized hospital with, say, 100,000 examinations per year, and if 30% of the patient dose could be saved with digital techniques and another 10% by avoidance of retakes, a substantial risk could be avoided and potential cost savings could be realized. With a typical mean effective dose per examination of (collectively, ), digital imaging, if used properly, could reduce the annual collective dose by . This annual reduction in collective dose for the same clinical benefit per hospital, supports the promotion and introduction of digital technology as fast as possible. The initial effort to train the staff in the use of digital techniques and the development of the necessary quality control program would be offset by the dose reduction and the workflow improvement. There are many valid reasons for introducing digital imaging into general radiography, but the claim that film/screen systems are unnecessarily hazardous is not one of them. Digital imaging for general radiography has many advantages compared with film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider dynamic range means that acceptable images may be acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose, and for too many images to be obtained, simply because the acquisition process is so easy. There are two aspects of the Point/Counterpoint proposition that can be challenged. The first is that digital imaging necessarily reduces patient doses, and the second is that film screens should be phased out as unnecessarily hazardous. Each of these is discussed below. In digital imaging, increasing patient dose generally means improving image quality because of reduced image noise. Digital imaging systems may be set up to produce higher quality images than necessary for diagnosis,6 and consequently patient doses may be higher than needed. The DIMOND project has proposed that digital radiography procedures should be classified in low, medium or high image quality bands.7 Advice is given on the speed class of the imaging modality to be used for each of these three bands. In these proposals, the speed class of a film/screen system for a given image quality band is the same as that of a storage-phosphor system, and one band lower than that for flat-panel detectors. The decrease in patient dose associated with the introduction of a flat-panel system for digital radiology lies in the range of 33–50% when replacing a film/screen system.8–10 Thus, even if flat-panels are used properly, the maximum reduction in patient dose is only a factor of two. Hence, screen/film systems should not be considered unnecessarily hazardous. The ease of image acquisition by digital systems can mean that there is an increase in the number of images acquired. This has happened in digital fluoroscopy.11 Digital radiology has also led to an unjustified increase in the number of procedures by 82%.12 In summary, there is evidence that the introduction of flat-panel detectors leads to a dose-reduction of typically 50%, but can lead to almost a doubling of the number of procedures. Hence, it is not reasonable to conclude that film/screen systems are unnecessarily hazardous, and the Point/Counterpoint proposition is untenable. The International Commission on Radiological Protection also has concerns about dose levels in digital radiology. These concerns are summarized in Publication 93.1 I agree in part with some of the points presented by Dr. Faulkner. The wide dynamic range of digital detectors means that acceptable images may be acquired at a range of dose levels and that overexposures may not be detected. But overexposures will be minimized with proper training programs and quality control, including frequent patient dose evaluations. In digital imaging increased patient dose generally means improved image quality due to reduced noise. Again, I agree that this could be misused if the required image quality is not defined for a specific medical task. With digital imaging, it is possible to select image quality (and radiation dose) using the same detector, which is not the case with film/screen. With this already “old” imaging technology, it is necessary to change the speed class of the film/screen combination and, in practice, more dose than is necessary is sometimes used. The example quoted by Dr. Faulkner of the European DIMOND project7 proposing the model of three image-quality bands in projection radiography (and corresponding dose levels of low, medium and high) is a clear advance in patient dose management. The ability to select low image quality for some clinical tasks, leading to a saving of 50% in patient dose, is not so readily available if film/screen systems are used. Dr. Faulkner points out the tendency in digital radiology to obtain more images than necessary (especially in fluoroscopy), but this again is a matter of appropriate training of the practitioners. Using a digital system and archiving short fluoroscopic sequences, a well-trained radiologist may complete a digestive or urological examination, for example, with fewer images and less patient dose compared with those for non-digital technology. I agree with Dr. Faulkner that film/screen systems are not “per se” unnecessarily hazardous, but it is clear that the added benefits of digital technology are enormous. These advantages, together with reduced doses, means that we should advise our health administrators to move in this direction. Professor Vano makes a series of important points in supporting the use of digital imaging for general radiography. I wholeheartedly agree with him that digital imaging should result in lower patient doses, provided that the technology is used appropriately. I concur that one of the main benefits of digital imaging is the large dynamic range compared with that for film/screen systems. The wide dynamic range means that it is possible to obtain acceptable images at a range of dose levels, reducing the need for repeat exposures. However, there is a tendency for digital systems to be used at higher dose levels than necessary, as users demand images of the highest quality rather than of a quality needed for diagnosis. Professor Vano is correct in endorsing the role of training; it is critical that users have an understanding of the technology of the system, if the potential for dose reduction associated with the use of digital technology is to be achieved in practice. Even if it is accepted that digital imaging can reduce doses by up to a factor of two, this level of dose reduction does not imply that film/screen systems are unnecessarily hazardous. There are many areas of radiology practice where local differences result in dose variations that are much greater than two, and several population surveys have shown that doses vary among centers by factors of 10–100. Placed in this context, film/screens should not be regarded as unnecessarily hazardous. There are valid reasons for replacing film/screen systems with digital detectors for general radiography, particularly for centers where there may be problems with the water supply that could impact on chemical processing of film. Professor Vano has eloquently made the case for change, but the case should not be based upon the proposition that film/screens are unnecessarily hazardous.
No takes yet. Share an insight, caveat, or question.
Vano et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: