Answers are grounded in this paper and cite their sources.
BACKGROUND: Wall shear stress (WSS) is an important hemodynamic marker of vascular disease, yet its accurate estimation in patient-specific geometries remains challenging. Because WSS is derived from the velocity gradient at the vessel wall, it is highly sensitive to how well the near-wall region is resolved. Finite-volume simulations on unstructured meshes can therefore yield inaccurate WSS values unless dedicated boundary-layer meshes are used, a difficulty that is amplified in complex, image-derived geometries where variations in vessel shape and curvature complicate gradient reconstruction at the wall. Methods that reconstruct wall velocity gradients accurately on irregular point distributions, without relying on specialized near-wall meshing, are therefore needed. PURPOSE: We present the meshfree Discretization-Corrected Particle Strength Exchange (DC PSE) methodology for accurate wall shear stress (WSS) computation in patient-specific vascular geometries represented by unstructured point clouds. METHODS: The proposed framework reconstructs spatial derivatives directly on irregular node distributions. The methodology is validated using fully developed Poiseuille flow, for which analytical solutions for both velocity and WSS are available. The proposed scheme is applied to transient blood flow simulations in patient-specific arterial geometries reconstructed from medical imaging. Mesh refinement convergence studies were performed to verify the accuracy and numerical robustness of the proposed approach. Velocity fields were computed by solving the incompressible Navier-Stokes equations using the OpenFOAM finite-volume solver, while WSS was evaluated from the reconstructed wall velocity gradients using the proposed DC PSE formulation. Numerical predictions were compared with WSS obtained directly from OpenFOAM. RESULTS: obtained with OpenFOAM post-processing tools using a reference finite-volume solution. The reconstructed velocity derivatives remained stable on irregular point distributions. In patient-specific blood flow simulations, the proposed framework produced smooth and physically consistent WSS distributions throughout the cardiac cycle, accurately resolving regions of elevated and low shear associated with vessel curvature and bifurcations. CONCLUSIONS: The DC PSE framework provides an accurate, robust, and computationally efficient approach for WSS estimation in image-based cardiovascular Computational Fluid Dynamics (CFD) simulations. By improving the reconstruction of wall velocity gradients on complex geometries, the proposed methodology substantially enhances the accuracy of wall-derived hemodynamic metrics without requiring specialized boundary-layer meshes. The method offers a flexible post-processing framework that can be readily integrated into existing CFD pipelines and has significant potential for patient-specific cardiovascular modeling and computational medical physics applications.
No takes yet. Share an insight, caveat, or question.
Starakas et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: