Answers are grounded in this paper and cite their sources.
The vibration response of equipment foundation structures is not only affected by the structural stiffness and mass, but also greatly influenced by the degree of a soil-foundation structural interaction. Furthermore, the vibratory performance of equipment foundation structures supported by pile systems largely depends on the soil-pile dynamic stiffness and damping, which are variable in nature within the speed range that machines operate at. This paper reviews a method for evaluating effective soil-pile stiffness and damping that can be computed by Novak’s method or by commercial software (DYNA6, University of Western Ontario). A series of Finite Element (FE) time history and steady-state analyses using SAP2000 have been performed to examine the effects of dynamic soil-pile-foundation interaction on the vibration performance of equipment foundations, such as large compressor foundations and steam/gas turbine foundations. Frequency-dependent stiffness is estimated to be higher than frequency-independent stiffness, in general, and, thus, affects the vibration calculation. This paper provides a full-spectrum steady-state vibration solution, which increases the reliability of the foundation’s structural design.
No takes yet. Share an insight, caveat, or question.
Song et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: