Why the study?
The impact of bioprosthesis design on hemodynamics and clinical outcomes in small aortic annuli after AVR was unclear.
Does the Trifecta bioprosthesis improve hemodynamics and clinical outcomes compared to the Carpentier-Edwards bioprosthesis in patients with small aortic annuli undergoing AVR?
Cohort (n=183)
Does the Trifecta bioprosthesis improve hemodynamics and clinical outcomes compared to the Carpentier-Edwards bioprosthesis in patients with small aortic annuli undergoing AVR?
Absolute Event Rate: 12.9% vs 15%
p-value: p=0.044
While the Trifecta valve offers better immediate postoperative hemodynamics than the Carpentier-Edwards valve in small aortic annuli, long-term hemodynamics and clinical outcomes are similar.
Lower initial gradients with Trifecta did not yield lasting hemodynamic or outcome differences; leaves open whether design affects durability beyond 3 years.
The Trifecta valve has externally mounted leaflets; it differs from classic internally mounted valves (e.g., Carpentier-Edwards [C-E]). We evaluated post-implantation hemodynamics and clinical outcomes of these bioprostheses in small aortic annuli. From January 2015 to April 2019, 490 patients who underwent aortic valve replacement (AVR) were reviewed retrospectively. Altogether, 183 patients received 19 or 21 mm diameter C-E (n = 121) or Trifecta (n = 62) prostheses. To minimize confounding variables, we performed propensity-score matching analysis. The mean transvalvular pressure gradient (TVPG) was significantly lower in the Trifecta than in the C-E group at discharge (12.9 ± 4.8 vs. 15.0 ± 5.3 mmHg, p = 0.044). TVPG change over time was not significantly different between groups (p = 0.357). Left ventricular mass index decreased postoperatively (reduction: C-E, 28.1%; Trifecta, 30.1%, p = 0.879). No late mortality, severe patient–prosthesis mismatch, moderate-to-severe paravalvular leakage, structural valve degeneration, or valve thromboses were observed. Freedom from valve-related events at 3 years were similar for C-E (97.9% ± 2.1%) and Trifecta (97.7% ± 2.2%) patients (log-rank p = 0.993). Bioprosthesis design for small annuli significantly affected TVPG immediately after AVR. However, hemodynamics over time and clinical outcomes did not differ between the two designs.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2021) conducted a cohort in Small aortic annuli requiring aortic valve replacement (n=183). Trifecta bioprosthesis vs. Carpentier-Edwards (C-E) bioprosthesis was evaluated on Mean transvalvular pressure gradient (TVPG) at discharge (p=0.044).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: