In this research work, diglycidyl ether of bisphenol-A (DGEBA) and polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene (PSPEB) were blended and loaded with purified graphene nanoplatelet (GNP-P) and acid-functionalized graphene nanoplatelet (GNP-F). Solution mixing route was used for nanocomposite processing with diaminodiphenylmethane as a hardener. According to SEM, inclusion of functional GNP-F depicted fine morphology due to interfacial adhesion between functional nanofiller and blend. Sharp increase in ultimate tensile strength and toughness was observed for DGEBA/PSPEB/GNP-F 0.03–0.1 system, i.e. 60.4–64.5 MPa and 422.6–725.5 MPa, respectively. For 0.1 wt.% GNP-P loading, Tmax was observed as 547 °C; whereas, GNP-F showed higher value of 568 °C. Glass transition temperature of acid functional system was also higher (258 °C) than purified one (229 °C). DGEBA/PSPEB/GNP-F 0.1 depicted semi-crystalline nature (12.5° and 19.1°). EMI shielding effectiveness of nanocomposite was sufficiently high in the range of ~17.9–20.07 dB, i.e. desired for aerospace applications. Moreover, introduction of 0.1 wt.% functional graphene nanoplatelet enhanced the electrical conductivity up to 0.14 cm−1.