Capnography is a non-invasive measurement of the partial pressure of carbon dioxide (PaCO2) in exhaled breath. Any change in end-tidal carbon dioxide (EtCO2) typically reflects in PaCO2. There are situations where EtCO2 values may be elevated or reduced.[1] We present an unusual scenario where EtCO2 value drastically dropped to zero while actual arterial carbon dioxide (CO2) was critically high. This was observed during bronchoscopic electrocoagulation and snaring of endotracheal tumour (size 43 mm × 31 mm × 32 mm) in a 51-year-old male under general anaesthesia. Written and informed consent for publication was obtained from the patient. Preoperatively, arterial blood gas (ABG) parameters (pH 7.371, PCO2 44.6 mm Hg, PO2 180.4 mm Hg, SO2 99.9% and HCO3 26.1 mmol/L) were within the normal limits on oxygen supplementation at 2 L/min through nasal prong. After preoxygenation, anaesthesia was induced with injection fentanyl 2 μg/kg, injection propofol 2 mg/kg and injection atracurium 0.5 mg/kg. A supraglottic device (I-gel) size 4 was inserted. Anaesthesia maintained with sevoflurane in the air–oxygen mixture of ratio 1:1. Pulmonologist started fibreoptic bronchoscopy through the suction port of the catheter mount. There was a rise in EtCO2 level due to hypoventilation during bronchoscopy. Thereafter, both EtCO2 value and capnograph were not recordable (Mindray, BeneVison N17, Shenzhen, China) [Figure 1]. The patient desaturated to SpO2 75%. Bronchoscope was immediately removed and manually ventilated with 100% FIO2.Figure 1: Anaesthesia work station showing maximum adjustable end-tidal carbon dioxide (EtCO2) alarm limit (a), maximum EtCO2 scale (b), zero EtCO2 during critically high partial pressure of carbon dioxide (c), irregular and flat line capnography (d)EtCO2 side stream sensor line and water trap were changed in view of line failure. However, monitor displayed zero EtCO2 with no graphical representation on capnometer, while SpO2 100% and vitals were within normal limit. The ABG showed severe respiratory acidosis with a pH 6.987, PCO2 175.6 mm Hg and pO2 107.2 mm Hg. Minute ventilation was increased to washout CO2. Procedure was continued under apnoeic oxygenation with intermittent manual positive pressure ventilation. ABG improved with decreasing trend of PaCO2. Gradually, the monitor displayed fluctuating EtCO2 values ranging from 94 to 57 mm Hg. Manual ventilation was continued till EtCO2 values reached 40 mm Hg. The causes of hypercapnia and hypoxaemia during bronchoscopic procedure include apnoeic spell, airway obstruction by bronchoscope itself or due to slipping of the resected intratracheal tumour.[2] EtCO2 monitoring aids in the early detection of apnoeic phases during sedation. However, in case of ventilation–perfusion mismatch, EtCO2 is insufficient to measure PaCO2.[2] EtCO2 also becomes unrecordable when alveolar ventilation volume is less than the anatomical dead space. However, in our case, it was unrecordable despite removing the bronchoscope. Incorrect EtCO2 due to sampling line blockade may result in misinterpretation of venous air embolism or pulmonary embolism.[3] A standard protocol is essential for identifying potential causes.[4] In our case, it was noticed that, maximum EtCO2 measuring scale and upper alarm limit were set at 50 mm Hg. This monitor had maximum measurable EtCO2 scale 80 mm Hg and maximum adjustable upper alarm limit of EtCO2 was 99 mm Hg [Figure 1]. The monitor displayed capnograph when PaCO2 came below the limit. We also observed that, the maximum measurable EtCO2 scale of another anaesthesia workstation (Drager primus ASKM-0097, Lubeck, Germany) is 75 mm Hg only. We recommend routine check of EtCO2 upper alarm limit before its use in difficult airway management, in which prolonged apnoea after preoxygenation may proceed. Manufacturer must joint a notice about the limitations of the device. The manufacturer may insert a message for the values beyond the measurable limit, like ‘out of range’ or too ‘high’. Similar messages appear with ABG, blood sugar, electrolytes, etc. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: