Key result
Continuous veno-venous haemodiafiltration reduced circuit failure rates compared to haemofiltration (43% vs 56%) and increased median circuit survival time (11 vs 2.75 hours; P<0.001).
Why the study?
Does continuous veno-venous haemodiafiltration improve failed circuit survival times and rates compared to continuous veno-venous haemofiltration in patients receiving renal replacement therapy?
Observational (n=78)
Does continuous veno-venous haemodiafiltration improve failed circuit survival times and rates compared to continuous veno-venous haemofiltration in patients receiving renal replacement therapy?
Hazard Ratio: 1.87 (95% CI 1.18–2.82)
Absolute Event Rate: 43% vs 56%
p-value: p=> 0.007
Continuous veno-venous haemodiafiltration significantly increased circuit survival times and reduced circuit failure rates compared to continuous veno-venous haemofiltration.
CVVHDF may extend circuit life in CRRT; leaves open superiority over haemofiltration pending randomized confirmation.
BACKGROUND: A significant problem during continuous renal replacement therapy is premature circuit failure, affecting efficacy and molecular clearance. Techniques to improve circuit failure are anticoagulation, access site and modality. A modality change was introduced, moving from continuous veno-venous haemofiltration to continuous veno-venous haemodiafiltration as a result of existing issues with failing circuit times and failure rates. AIM: The aim of this service evaluation was to ascertain if the use of continuous veno-venous haemodiafiltration compared to continuous veno-venous haemofiltration had affected failed circuit survival times and rates. METHODS: A service evaluation was chosen because the focus was to ascertain what effect a practice change had had on a particular service. The service evaluation was registered with the local trust's audit department and gained university ethical approval. It was anticipated that the data generated would be used to inform, question and improve practices. Patients who received renal replacement therapy (RRT) from May 2012 to January 2013 were retrospectively identified. Patients received continuous veno-venous haemofiltration for the duration of their treatment before September 2012 and continuous veno-venous haemodiafiltration after. A total of 78 patients were identified as receiving RRT; 41 of these patients had failed circuits. RESULTS: A total of 182 failed circuits were analysed. The median duration of failed circuits during continuous veno-venous haemofiltration was shorter (2·75 h, standard deviation (SD) = 13·82) when compared to continuous veno-venous haemodiafiltration (11 h, SD = 15·26, p < 0·001, 95% confidence interval (CI) 2·5-10). Circuit failure rate in continuous veno-venous haemofiltration was 56% compared to 43% in continuous veno-venous haemodiafiltration. After performing a Cox regression analysis, continuous veno-venous haemofiltration appeared to have a 1·87 times (CI 1·18-2·82, p > 0·007) more likely chance of failure. CONCLUSION: The use of continuous veno-venous haemodiafiltration has had an overall positive effect on the haemofiltration service by reducing the number of failed circuits and increasing circuit survival times, which may have improved the efficacy of the service. Continuous veno-venous haemodiafiltration may be a more appropriate modality of choice in non-septic patients requiring prolonged continuous RRT episodes.
No takes yet. Share an insight, caveat, or question.
Ede et al. (2016) conducted an observational in Renal replacement therapy (n=78). Continuous veno-venous haemodiafiltration vs. Continuous veno-venous haemofiltration was evaluated on Circuit failure rate (HR 1.87, 95% CI 1.18-2.82, p=> 0.007). Continuous veno-venous haemodiafiltration reduced circuit failure rates compared to haemofiltration (43% vs 56%) and increased median circuit survival time (11 vs 2.75 hours; P<0.001).