Key result
Pulse oximetry fails to screen for asymptomatic lower extremity artery disease in type 2 diabetes.
Why the study?
The utility of pulse oximetry for screening undiagnosed lower extremity artery disease in type 2 diabetic patients was uncertain.
Does pulse oximetry accurately screen for asymptomatic lower extremity artery disease in type 2 diabetic patients?
Cross-Sectional (n=594)
No
Does pulse oximetry accurately screen for asymptomatic lower extremity artery disease in type 2 diabetic patients?
Pulse oximetry is not useful for screening asymptomatic lower extremity artery disease in patients with type 2 diabetes.
Pulse oximetry lacks support for screening; cross-sectional data leave validation of better noninvasive tools open to prospective study.
Objectives: To determine the of undiagnosed lower extremity artery disease using the pulse oximetry in a type 2 diabetic population sample.Methods: Observational, cross-sectional, descriptive study that included 594 type 2 diabetic patients, with no previous history of lower extremity artery disease.Medical history, physical examination, determination of the ankle-brachial index (portable Doppler) and measurement of oxygen saturation in upper and lower extremities (pulse oximeter) were performed.Results: Frequency of lower extremity artery disease determined by ankle-brachial index was 18.4%.No significant correlations were detected between oxygen saturation and the ankle-brachial index except for the relationship between ankle-brachial index vs.oxygen saturation at 30 cm lower limb elevation vs. the supine position at no elevation (0 cm) in subjects under the age of 40.Pulse oximetry showed little diagnostic value in the screening of lower extremity artery disease.A relationship between lower extremity artery disease and age has been found.Its diagnosis was associated with a lower body mass index and lower systolic blood pressure in the lower extremities and higher in the upper extremities.Conclusions: We conclude that pulse oximetry is not useful in the screening for asymptomatic lower extremity artery disease in type 2 diabetics.
No takes yet. Share an insight, caveat, or question.
Fernández et al. (2021) conducted a cross-sectional in Type 2 diabetes (n=594). Pulse oximetry vs. Ankle-brachial index (ABI) was evaluated on Area under the ROC curve (AUC) for toe-to-finger oxygen saturation difference (TTF) to predict lower extremity artery disease (AUC 0.525, 95% CI 0.476-0.573). Pulse oximetry is not useful in screening for asymptomatic lower extremity artery disease in type 2 diabetics, demonstrating poor diagnostic accuracy with an AUC of 0.525.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: