Key result
Rapid ventricular pacing triggers AF in ~18% of VF induction tests, terminated by subsequent ICD shocks.
Why the study?
The frequency and clinical relevance of atrial fibrillation induced by rapid high voltage ventricular pacing during ventricular fibrillation conversion testing were unclear.
Does rapid high voltage ventricular pacing induce atrial fibrillation during ventricular fibrillation conversion testing in patients receiving a dual chamber ICD?
Observational (n=50)
Does rapid high voltage ventricular pacing induce atrial fibrillation during ventricular fibrillation conversion testing in patients receiving a dual chamber ICD?
Rapid high voltage ventricular pacing for VF induction frequently induces AF, which is a non-specific phenomenon reliably terminated by the subsequent defibrillation shock.
Answers are grounded in this paper and cite their sources.
Transient AF during VF induction testing is reliably terminated by shock; hypothesis-generating and should not yet change dual-chamber ICD protocols.
OBJECTIVE: To assess whether rapid high voltage ventricular pacing can also induce atrial fibrillation, and whether the induction of atrial fibrillation during ventricular fibrillation conversion testing is related to the patient's heart disease. DESIGN: Prospective study of 50 patients who received the dual chamber implantable cardioverter-defibrillator (ICD) Ventak AV II DR (Guidant) as a first implant. This device can record atrial activity even during a ventricular fibrillation episode and can induce atrial fibrillation by rapid atrial bursts. MAIN OUTCOME MEASURES: Frequency of atrial fibrillation after induction of ventricular fibrillation; clinical characteristics of patients with and without induced atrial fibrillation; frequency of atrial fibrillation induced by rapid atrial bursts during predischarge testing. RESULTS: Atrial fibrillation was observed in 40 of the 217 ventricular fibrillation episodes (18%) that could be detected immediately after delivery of high voltage pacing. The biphasic ICD shock for termination of ventricular fibrillation also terminated the atrial fibrillation in all cases. The 40 episodes of simultaneous atrial and ventricular fibrillation occurred in 18 patients (36%). The distribution of the clinical characteristics of the patients and the inducibility of atrial fibrillation during predischarge testing were similar in those with and without induced atrial fibrillation. CONCLUSIONS: Rapid high voltage ventricular pacing frequently induces atrial fibrillation, which was terminated by the subsequent biphasic ICD shock. The induction of atrial fibrillation seems to be a non-specific phenomenon, unrelated to the clinical status of the patient.
No takes yet. Share an insight, caveat, or question.
Schuchert et al. (2000) conducted an observational in Patients receiving a dual chamber implantable cardioverter-defibrillator (n=50). Rapid high voltage ventricular pacing was evaluated on Frequency of atrial fibrillation after induction of ventricular fibrillation. Rapid high voltage ventricular pacing frequently induced atrial fibrillation, which was consistently terminated by the subsequent biphasic ICD shock.
Synapse has enriched 10 related papers. Consider them for comparative context: