Answers are grounded in this paper and cite their sources.
Constant-current/constant-voltage (CC/CV) charging requires an inductive power transfer (IPT) converter to maintain the desired output characteristic and high efficiency over a wide range of operating-point load conditions. To address this challenge, this paper proposes a multimode reconfigurable IPT topology for high-power wireless charging of automated guided vehicles (AGVs). The topology coordinates reconfiguration between LCC–LCC and LCC–S compensation networks with full-bridge/half-bridge operation on both the inverter and rectifier sides, establishing three operating modes for low-load CC, higher-load CC, and high-load CV charging without a cascaded output DC–DC converter. A hybrid mode-switching strategy is further developed: the Mode 1/2 boundary is selected at the equal-efficiency point to preserve wide-range efficiency, whereas the Mode 2/3 boundary is selected at the equal-power point to reduce the CC-to-CV transition-power discontinuity. Experimental results obtained with resistive load banks over 3–144 Ω show that the hybrid strategy maintains a measured power-stage DC–DC efficiency of 91.72–94.95%. Compared with fixed single-mode operation over the same range, the hybrid strategy increases the minimum measured efficiency from 85.70% to 91.72%, an improvement of 6.02 percentage points. The prototype achieves a maximum output power of 15.26 kW at 94.71% efficiency, demonstrating the feasibility of the proposed reconfigurable approach for high-power, wide-load-range AGV wireless charging.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: