Percutaneous stenting of the carotid artery with embolic protection devices resulted in a 1.1% rate of in-hospital stroke/death and 30-day ipsilateral stroke/death, with a 3.4% overall complication rate.
Observational (n=442)
Carotid artery stenting using embolic protection devices demonstrates high procedural success and low rates of 30-day stroke or death, though device-specific complications remain a risk.
Background and Purpose-Periprocedural embolization of debris during carotid stenting interventions may result inneurological deficit.This study was designed to evaluate in-hospital and 30-day adverse events in patients percutaneously treated for carotid artery disease with embolic protection devices.Methods-From 1999 to June 2002, a total of 442 consecutive patients underwent percutaneous angioplasty and/or stenting of the extracranial carotid artery.The endovascular procedure was conducted under embolic protection devices.Results-The percutaneous procedure was successful in 440 of 442 patients (99.5%).No periprocedural death occurred with any embolic protection device.All in-hospital stroke/death and 30-day ipsilateral stroke/death rate was 1.1%.The overall complication rate was 3.4%.Major adverse events included 1 major stroke (0.2%), 4 intracranial hemorrhages (0.9%), 1 carotid artery wall fissuration (0.2%), and 1 diffuse cardioembolism (0.2%).Minor adverse events included 4 minor strokes (0.9%) and 4 transient ischemic attacks (0.9%).The cerebral protection device-related complications were 4 (0.9%): 1 case of abrupt closure of the internal carotid artery because of spiral dissection (0.2%), 1 case of trapped guide wire (0.2%), and 2 cases of intimal dissection (0.5%).Transient loss of consciousness, tremors, and fasciculations were present in 6 of 40 patients (15%) in whom occlusive protection devices were used.Conclusions-Our data suggest that percutaneous stenting of the carotid artery when a cerebral protection device is used is feasible and effective but not without potential complications.However, a long learning curve may exist for the proper use of some embolic protection devices.(Stroke.2003;34:1936-1943.
No takes yet. Share an insight, caveat, or question.
Eckert et al. (2003) conducted an observational in Carotid artery disease (n=442). Percutaneous angioplasty and/or stenting with embolic protection devices was evaluated on In-hospital stroke/death and 30-day ipsilateral stroke/death. Percutaneous stenting of the carotid artery with embolic protection devices resulted in a 1.1% rate of in-hospital stroke/death and 30-day ipsilateral stroke/death, with a 3.4% overall complication rate.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: