Key result
Targeted IL-18 microbubbles increase plaque contrast intensity ~17% over control microbubbles.
Why the study?
The study investigated whether targeted interleukin-18 ultrasonic microbubbles can improve molecular imaging of atherosclerotic plaques.
Does targeted IL-18 ultrasonic microbubbles improve molecular imaging of atherosclerotic plaques in a rabbit model?
Does targeted IL-18 ultrasonic microbubbles improve molecular imaging of atherosclerotic plaques in a rabbit model?
Targeted IL-18 ultrasonic microbubbles significantly improve the detection and contrast-enhanced intensity of atherosclerotic plaques in a rabbit model compared to control microbubbles.
Answers are grounded in this paper and cite their sources.
May aid preclinical plaque imaging in rabbits; leaves open translation to human molecular imaging.
Objective To investigate whether targeted interleukin-18 (IL-18) ultrasonic microbubbles can improve molecular imaging of atherosclerotic plaques. Methods An atherosclerotic plaque rabbit model was established using a high-fat diet and immunologic injury method. The locations of atherosclerotic plaques were verified by ultrasonography. Targeted IL-18 ultrasonic microbubbles were prepared by the biotin-avidin method. After being anesthetized, the experimental rabbits were randomized to use control microbubbles (MBc) and targeted microbubbles (MBt) to perform contrast-enhanced ultrasound examination of atherosclerotic plaques. After rabbits were sacrificed, the targeted plaques were taken for pathological examination and Western-blotting analysis. Results The atherosclerosis model was successfully constructed in 10 experimental rabbits. Light microscope showed stable physical properties of MBt and fluorescence microscopy showed uniform green halos on the surface of MBt. Semiquantitative analysis of contrast-enhanced intensity of targeted plaques revealed that the average intensity of MBc group was 202 ± 18, and that of MBt group was 237 ± 7. The difference was statistically significant (t=6.472, P < 0.001). Pathological examination indicated atheromatous plaques in the lumen of arteries; Western-blotting analysis indicated IL-18 expressions in the plaques. Correlation analysis showed contrast-enhanced intensity of MBc group and IL-18 expression in the plaques had no correlation (r=0.534, P=0.112), while that of MBt group and IL-18 expression had linear positive correlation (r=0.904, P < 0.001). Conclusion MBt can better facilitate the detection of atherosclerotic plaques than MBc and be used for early, sensitive and specific diagnosis and treatment of atherosclerotic plaques.
No takes yet. Share an insight, caveat, or question.
Jiang et al. (2018) studied Atherosclerotic plaques (n=10). Targeted interleukin-18 (IL-18) ultrasonic microbubbles (MBt) vs. Control microbubbles (MBc) was evaluated on Contrast-enhanced intensity of targeted plaques (p=< 0.001). Targeted IL-18 ultrasonic microbubbles increased the contrast-enhanced intensity of atherosclerotic plaques compared to control microbubbles.
Synapse has enriched 10 related papers. Consider them for comparative context: