Key result
MedLAB-CT transaortic implantation with CABG is linked to ~43% shorter aortic clamping time versus mechanical AVR.
Why the study?
The comparative hospital outcomes of open transaortic implantation of the MedLAB-CT prosthesis combined with CABG versus AVR with a mechanical prosthesis and CABG in patients with combined coronary artery disease were not well established.
Does open transaortic implantation of the MedLAB-CT prosthesis combined with CABG reduce procedural times compared to mechanical AVR with CABG in patients with combined coronary artery disease?
Observational (n=159)
No
Does open transaortic implantation of the MedLAB-CT prosthesis combined with CABG reduce procedural times compared to mechanical AVR with CABG in patients with combined coronary artery disease?
Open transaortic implantation of the MedLAB-CT prosthesis combined with CABG significantly reduces cardiopulmonary bypass and aortic clamping times compared to mechanical AVR with CABG.
Answers are grounded in this paper and cite their sources.
Supports TAVI feasibility in CHD patients; leaves open need for RCTs to guide practice.
Introduction. Aortic valve replacement (AVR) is one of the most frequently performed procedures in cardiac surgery, which significantly improves the quality of life and increases its duration. Recently, transcatheter aortic valve implantation (TAVI) has been actively used, which is especially important in patients with concomitant pathology, in particular coronary heart disease (CHD). In this article, we describe the experience of successful surgical treatment of patients who underwent TAVI in combination with coronary artery bypass grafting. Aim: To compare the results of open transaortic implantation of the “MedLAB–CT” prosthesis in combination with coronary bypass surgery, in comparison with similar indicators when replacing the aortic valve with a mechanical prosthesis with coronary artery bypass grafting, at the hospital stage. Material and Methods. Patients operated in the clinic from June 2020 to November 2023. A retrospective observational comparison of the results of surgical treatment of two groups of patients was performed: Group 1 study group, which consisted of 60 patients who underwent open transaortic implantation of the prosthesis “MedLAB-CT” in combination with CABG. Group 2 control group, it included 99 patients who underwent AVR with a mechanical prosthesis and CABG. Using the Propensity Score Matching (PSM) pseudorandomization method, 60 patients were selected from the comparison group. Results. Cardiopulmonary bypass time was significantly less in the “MedLAB-CT” + CABG group – 57.4 ± 8.3 min (p = 0.003). A statistical difference in the time of aortic clamping was revealed: in the study group had a value of 43.2 ± 5.2 min, in the comparison group 75.4 ± 9.2 min (p = 0.002). There were no statistically significant differences in the duration of surgery (p = 0.224), length of stay in the intensive care unit (p = 0.805) and hospitalization (p = 0.783). Conclusion. The proposed method of open transaortic implantation of the MedLAB-CT prosthesis in combination with coronary bypass surgery can significantly reduce the time of cardiopulmonary bypass and myocardial ischemia, which has a positive effect on the course of the postoperative period.
No takes yet. Share an insight, caveat, or question.
Базылев et al. (2025) conducted an observational in Aortic valve disease with concomitant coronary heart disease (n=159). Open transaortic implantation of the MedLAB-CT prosthesis in combination with CABG vs. Aortic valve replacement with a mechanical prosthesis and CABG was evaluated on Time of aortic clamping (p=0.002). Open transaortic implantation of the MedLAB-CT prosthesis with CABG reduced aortic clamping time compared to mechanical prosthesis with CABG.
Synapse has enriched 10 related papers. Consider them for comparative context: