We present a nanocomposite strain sensor (NCSS) to develop a novel structural health monitoring (SHM) sensor that can be easily installed in a composite structure. An NCSS made of a multi-walled carbon nanotubes (MWCNT)/epoxy composite was installed on a target structure with facile processing. We attempted to evaluate the NCSS sensing characteristics and benchmark compared to those of a conventional foil strain gauge. The response of the NCSS was fairly good and the result was nearly identical to the strain gauge. A neuron, which is a biomimetic long continuous NCSS, was also developed, and its vibration response was investigated for structural damage detection of a composite cantilever. The vibration response for damage detection was measured by tracking the first natural frequency, which demonstrated good result that matched the finite element (FE) analysis.
No takes yet. Share an insight, caveat, or question.
Choi et al. (2016) studied this question.