Key result
FilterWire EZ clot extraction before PCI achieves 100% procedural success in acute MI.
Why the study?
PCI in patients with acute MI is associated with higher incidence of distal embolization, no-reflow, or slow flow partly due to clot burden, motivating evaluation of clot extraction feasibility and safety.
Does clot extraction using the FilterWire EZ device prior to PCI improve angiographic outcomes and safety in patients with acute myocardial infarction?
Observational (n=15)
Does clot extraction using the FilterWire EZ device prior to PCI improve angiographic outcomes and safety in patients with acute myocardial infarction?
Primary clot extraction using the FilterWire EZ device prior to PCI in acute MI is feasible and effectively restores TIMI 3 flow without distal embolization.
FilterWire EZ clot extraction appears feasible before PCI in acute MI; hypothesis-generating, requires randomized trials before any clinical adoption.
OBJECTIVES: To test the feasibility, safety, and in-hospital outcomes of utilizing the FilterWire EZ to extract clot prior to percutaneous coronary intervention (PCI) in patients presenting with acute myocardial infarction (MI). BACKGROUND: PCI in patients with acute MI is associated with a higher incidence of distal embolization, no-reflow, or slow flow partly due to the presence of clot burden. METHODS: The authors describe the feasibility, safety, and outcomes of using a FilterWire EZ distal protection device as a clot extraction device in patients who presented with acute MI and documented clot on coronary angiography. RESULTS: Fifteen consecutive male patients with a mean age of 54 +/- 8 years presented with acute MI (60% ST elevation MI). MI involved left anterior descending artery (n = 4), circumflex artery (n = 3), and right coronary artery (n = 8). Clot extraction followed by PCI reduced the percent diameter stenosis from 94 +/- 12 to 65 +/- 11 (P < 0.001) and restored TIMI 3 flow in all patients without distal embolization. The angiographic, procedural, and clinical success rates were 100%. The mean left ventricular ejection fraction (LVEF) was 52 +/- 8% (range 30-62%) with only three patients (15%) who had an LVEF <50% and five patients (33%) without apparent wall motion abnormalities on echocardiography. CONCLUSIONS: Clot extraction before PCI during acute MI in native coronaries is feasible, safe, and effective in restoring TIMI 3 flow without distal embolization. Whether this approach results in better outcomes and improved LV function compared with standard therapy alone requires further investigation.
No takes yet. Share an insight, caveat, or question.
Aqel et al. (2008) conducted an observational in acute myocardial infarction (n=15). Clot extraction using FilterWire EZ distal protection device prior to PCI was evaluated on Angiographic, procedural, and clinical success. Clot extraction using the FilterWire EZ prior to PCI in acute MI reduced percent diameter stenosis from 94% to 65% (P<0.001) and achieved 100% angiographic, procedural, and clinical success.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: