Key result
ACCmax accurately identifies ≥70% ICA stenosis but falls short of conventional Doppler for ≥50% stenosis.
Why the study?
Local distorting factors such as vascular calcification can influence the ability to obtain conventional Doppler ultrasonography measurements for diagnosing internal carotid artery stenosis, motivating evaluation of the maximal systolic acceleration (ACCmax) parameter.
Does Doppler-derived maximal systolic acceleration (ACCmax) accurately quantify internal carotid artery stenosis compared to conventional Doppler parameters and CT-angiography?
Observational
No
Does Doppler-derived maximal systolic acceleration (ACCmax) accurately quantify internal carotid artery stenosis compared to conventional Doppler parameters and CT-angiography?
ACCmax is a useful adjunctive Doppler parameter for diagnosing severe (≥70%) internal carotid artery stenosis, particularly when local distorting factors hamper conventional measurements, though it is slightly inferior for moderate (≥50%) stenosis.
Answers are grounded in this paper and cite their sources.
ACCmax may adjunctively aid severe ICA stenosis diagnosis when conventional measures falter; leaves open routine adoption versus standard parameters.
OBJECTIVE: Doppler ultrasonography (DUS) is used as initial measurement to diagnose and classify carotid artery stenosis. Local distorting factors such as vascular calcification can influence the ability to obtain DUS measurements. The DUS derived maximal systolic acceleration (ACCmax) provides a different way to determine the degree of stenosis. While conventional DUS parameters are measured at the stenosis itself, ACCmax is measured distal to the internal carotid artery (ICA) stenosis. The value of ACCmax in ICA stenosis was investigated in this study. MATERIAL AND METHODS: All carotid artery DUS studies of a tertiary academic center were reviewed from October 2007 until December 2017. Every ICA was included once. The ACCmax was compared to conventional DUS parameters: ICA peak systolic velocity (PSV), and PSV ratio (ICA PSV/ CCA PSV). ROC-curve analysis was used to evaluate accuracy of ACCmax, ICA PSV and PSV ratio as compared to CT-angiography (CTA) derived stenosis measurement as reference test. RESULTS: 0.87) were found. In ROC subanalysis, the ACCmax had a sensitivity of 90% and a specificity of 89% to diagnose a ≥70% ICA stenosis, and a sensitivity of 82% and a specificity of 88% to diagnose a ≥50% ICA stenosis. For diagnosing a ≥50% ICA stenosis the area under the curve (AUC) of ACCmax (0.88) was significantly lower than the AUC of PSV ratio (0.94) and ICA PSV (0.94). To diagnose a ≥70% ICA stenosis there were no significant differences in AUC between ACCmax (0.89), PSV ratio (0.93) and ICA PSV (0.94). CONCLUSIONS: ACCmax is an interesting additional DUS measurement in determining the degree of ICA stenosis. ACCmax is measured distal to the stenosis and is not hampered by local distorting factors at the site of the stenosis. ACCmax can accurately diagnose an ICA stenosis, but was somewhat inferior compared to ICA PSV and PSV ratio to diagnose a ≥50% ICA stenosis.
No takes yet. Share an insight, caveat, or question.
Brouwers et al. (2021) conducted an observational in Internal Carotid Artery Stenosis. Maximal systolic acceleration (ACCmax) vs. ICA peak systolic velocity (PSV) and PSV ratio was evaluated on Accuracy (AUC) for diagnosing ≥50% and ≥70% ICA stenosis compared to CT-angiography. Maximal systolic acceleration (ACCmax) accurately diagnosed ≥70% ICA stenosis similarly to conventional parameters, but was inferior to PSV ratio and ICA PSV for ≥50% stenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: