Key result
Extracorporeal autoperfusion matches direct renal artery flow probes for measuring renal hemodynamics.
Why the study?
A method for continuous measurement of renal blood flow in anesthetized rats without renal artery dissection was needed to evaluate renal vascular control.
Does extracorporeal autoperfusion allow continuous measurement of renal blood flow and vascular responses in anesthetized rats compared to direct flow probe placement?
Does extracorporeal autoperfusion allow continuous measurement of renal blood flow and vascular responses in anesthetized rats compared to direct flow probe placement?
The described extracorporeal autoperfusion method allows for continuous measurement of renal blood flow and evaluation of renal vascular control in rat models without dissection of the renal artery.
Answers are grounded in this paper and cite their sources.
Supports extracorporeal autoperfusion for renal hemodynamics in rat models; leaves open translation to clinical or larger-animal studies.
A method is described for continuous measurement of renal blood flow in the anesthetized rat without dissection of the renal artery. Blood flow and arterial pressure were measured in an extracorporeal flow circuit between the carotid artery and an aortic pouch from which the left renal artery was the only outlet. Injection into the flow circuit allowed delivery of drugs directly into the arterial blood supply of the kidney. Electrical stimulation of undamaged periarterial renal kidney. Electrical stimulation of undamaged periarterial renal nerves was possible since the renal artery remained undisturbed. Extracorporeal autoperfusion of the rat kidney produced renal flow and resistance measurements that did not differ from those obtained with a flow probe placed directly on the renal artery. Renal nerve stimulation was found to cause renal vasoconstriction due to activation of alpha-adrenergic receptors by norepinephrine released from postganglionic sympathetic neurons. Renal vascular responses to a variety of intra-arterial vasoactive agents were also determined. The method described here allows the evaluation of renal vascular control in the variety of disease states for which suitable rat models have been developed.
No takes yet. Share an insight, caveat, or question.
Fink et al. (1978) studied this question. Extracorporeal autoperfusion method vs. Flow probe placed directly on the renal artery was evaluated on Renal flow and resistance measurements. Extracorporeal autoperfusion of the rat kidney produced renal flow and resistance measurements that did not differ from those obtained with a flow probe placed directly on the renal artery.
Synapse has enriched 10 related papers. Consider them for comparative context: