January 1, 1982Clinical and Experimental Hypertension

Measurement of Renal Artery Pressure in the Rat

View Full Paper
Ask AI
Bookmark
Share

Key result

Direct measurement of renal artery pressure using a glass micropipette yielded an average of 103.8 mmHg compared to 107.2 mmHg from a femoral artery catheter (P<0.05), without altering renal blood flow.

Population

13 Sprague-Dawley rats

Comparison

Direct measurement of renal artery pressure… vs Femoral artery catheter and contralateral right…

Design

Preclinical

Authors

WMWilliam R. MurphyWichita State UniversityKSK. A. StanekNorthwest Medical RehabilitationTCThomas G. ColemanUniversity of Mississippi Medical Center

Discussion

Loading...

Member takes

Implication

Micropipette renal pressure measurement is feasible in rats without flow disruption; leaves open translation to clinical hypertension research.

Structured PICO

P
Population
13 Sprague-Dawley rats used to develop and document a technique for direct measurement of renal artery pressure.
I
Intervention
Direct measurement of renal artery pressure (RAP) using a glass micropipette fitted to a low displacement pressure transducer
C
Comparator
Femoral artery catheter (for pressure comparison) and contralateral right kidney (for blood flow comparison)
O
Outcome
Renal artery pressure and renal blood flow (RBF) measured using radiolabeled microspheressurrogate

Main Result

Absolute Event Rate: 103.8% vs 107.2%

p-value: p=<0.05

A glass micropipette fitted to a low displacement pressure transducer provides an accurate method for direct measurement of renal artery pressure in rats without altering renal blood flow.

Cite This Study

Murphy et al. (1982) studied this question. Direct measurement of renal artery pressure using a glass micropipette vs. Femoral artery catheter was evaluated on Renal artery pressure compared to mean arterial pressure (p=<0.05). Direct measurement of renal artery pressure using a glass micropipette yielded an average of 103.8 mmHg compared to 107.2 mmHg from a femoral artery catheter (P<0.05), without altering renal blood flow.

synapsesocial.com/papers/6a9a40dec455948676de8d97https://doi.org/10.3109/10641968209060794
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Reversible Renovascular Hypertension and Renal Arterial Pressure1974 · 20 citations
  2. 2Renal Hemodynamics and Plasma Renin Activity after Renal Artery Constriction in Conscious Dogs1972 · 27 citations
  3. 3Intrarenal renin-angiotensin-sodium interdependent mechanism controlling postclamp renal artery pressure and renin release in the conscious dog with chronic one-kidney Goldblatt hypertension.1977 · 22 citations
  4. 4Inhibition of angiotensin conversion and prevention of renal hypertension1975 · 100 citations
  5. 5Angiotensin-Sodium Interaction in Blood Pressure Maintenance of Renal Hypertensive and Normotensive Rats1973 · 291 citations