The current study aims to improve the performance of simple methods for the estimation of daily reference evapotranspiration (ET0) in humid East China, namely Priestley–Taylor 1972 (P-T 1972), Hargreaves–Samani 1985 (H-S 1985) and Turc 1961 (TU 1961). These methods were evaluated and calibrated based on well-watered grass lysimeter experiments. The FAO-56 Penman–Monteith equation (FAO-56 PM) is the best method, and the radiation-based methods (TU 1961 and P-T 1972) perform much better than the temperature-based method (H-S 1985). In the simple methods, the coefficients are calibrated to: 1.34 for P-T 1972; 0.0186, 23.47 and 17.06 for TU 1961; and 0.0027 and 0.449 for H-S 1985. The locally calibrated TU 1961 and P-T 1972 perform much better than the original, with either the observed ET0r or the ET0c obtained by FAO-56 PM as standard. However, local calibration does not significantly improve the performance of the H-S 1985 method. In humid East China, FAO-56 PM is the best method for daily ET0 calculation. TU 1961, especially if locally calibrated, is the optimal choice as a simple substitute for FAO-56 PM when solar radiation is available. Otherwise, serious local calibration is strongly recommended before applying H-S 1985 for daily ET0 estimation.