Key result
Standalone LAAC matches combined procedures for stroke, systemic embolism, and CV death.
Why the study?
Multiple cardiac conditions are frequent among elderly patients and simultaneous treatment with LAAC and other interventions to ensure favorable outcomes requires evaluation.
Does combining left atrial appendage closure with other structural or coronary interventions affect procedural safety and long-term efficacy compared to LAAC as a single procedure?
Cohort (n=559)
Yes
Does combining left atrial appendage closure with other structural or coronary interventions affect procedural safety and long-term efficacy compared to LAAC as a single procedure?
Combining left atrial appendage closure with other structural, coronary, or electrophysiological procedures yields comparable safety and long-term efficacy to performing LAAC as a standalone procedure.
Comparable efficacy in this cohort does not support routine combined LAAC; hypothesis-generating and requires randomized confirmation.
OBJECTIVES: This study compares procedural and late clinical outcomes of left atrial appendage closure (LAAC) with Amplatzer devices as a single versus a combined procedure with other structural or coronary interventions. BACKGROUND: Multiple cardiac conditions are frequent among elderly patients and invite simultaneous treatment to ensure a favorable patient outcomes. METHODS: 559 consecutive patients (73.3 ± 11.1 years) underwent LAAC with Amplatzer devices at two centres (Bern and Zurich university hospitals, Switzerland) either as a single procedure or combined with other interventions. The primary safety endpoint was a composite of major peri-procedural complications and major bleeding at follow-up, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. All event rates are reported per 100 patient-years. RESULTS: In 263 single and 296 combined procedures with percutaneous coronary interventions (47.6%), closure of an atrial septal defect (8.4%) or a patent foramen ovale (36.5%), transcatheter aortic valve implantation (10.1%), mitral clipping (4.1%), atrial fibrillation ablation (8.8%), or another procedure (3.0%) were analyzed. Device success (96.6% [single] vs. 99.0% [combined], p = .08) did not differ between the groups. After a mean follow-up of 2.6 ± 1.5 vs. 2.5 ± 1.5 years and a total of 1,422 patient-years, the primary efficacy (40/677, 5.9% [single] vs. 37/745, 5.0% [combined]; HR, 1.2, 95% CI, 0.8-1.9, p = .44), as well as the primary safety endpoint (25/677, 3.7% vs 28/745, 3.8%; HR, 1.0, 95% CI, 0.6-1.8, p = .89) were comparable. CONCLUSIONS: LAAC with Amplatzer devices combined with structural, coronary, and electrophysiological procedures offers procedural feasibility and safety, as well as long-term efficacy.
No takes yet. Share an insight, caveat, or question.
Kleinecke et al. (2020) conducted a cohort in Patients undergoing left atrial appendage closure (n=559). Left atrial appendage closure (LAAC) as a single procedure vs. LAAC combined with other structural or coronary interventions was evaluated on Composite of stroke, systemic embolism, and cardiovascular/unexplained death (HR 1.2, 95% CI 0.8-1.9, p=0.44). Left atrial appendage closure as a single procedure showed comparable efficacy to combined procedures for stroke, systemic embolism, and cardiovascular death (HR 1.2; 95% CI 0.8-1.9; p=0.44).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: