Key result
Higher QRS Index is linked to ~6% greater odds of echocardiographic response to CRT.
Why the study?
The association between QRS narrowing and response to cardiac resynchronization therapy remains inconclusive, motivating exploration of the QRS Index's predictive value.
Does the QRS Index predict echocardiographic response in patients undergoing CRT-D implantation?
Observational (n=326)
Yes
Does the QRS Index predict echocardiographic response in patients undergoing CRT-D implantation?
The QRS Index, reflecting the relative shortening of QRS duration after CRT implantation, is an independent predictor of echocardiographic response.
QRS Index may aid CRT response prediction; hypothesis-generating and requires prospective validation before clinical adoption.
BACKGROUND: The association between QRS narrowing and response to cardiac resynchronization therapy (CRT) has been investigated by several studies, but their findings remain inconclusive. Aim of our study was to explore the relationship between QRS Index and echocardiographic response to CRT.METHODS: This multicenter, retrospective analysis included 326 consecutive patients (mean age was 70.0±10.1 years old; males 76.7%) who underwent CRT-D implantation in primary and secondary prevention between 2018 and 2020. The estimation of QRS shortening after CRT-D implantation was precisely assessed through the QRS Index, calculated as follows: [(QRS duration before implantation - paced QRS duration)/QRS duration before implantation]*100.RESULTS: After a mean follow-up of 12.7±4.5 months, 55.2% (180/326) of the patients showed an echocardiographic response to CRT. The median [25-75th] QRS Index was 3.85% [-14.1% - +13.9%]. The best predictive cut-off value of QRS Index was 1.40% (sensitivity 70.4%, specificity 64.5%, AUC 0.70). In patients with left bundle branch block, the median [25-75th] QRS Index was 9.85% [+3.87% - +16.7%]. In this subgroup, the AUC was 0.737 and the best predictive cut-off of QRS Index was 2.20% (sensitivity 78.3%, specificity 67%). The multivariable model showed that only left ventricular ejection fraction and QRS Index were independently associated with CRT response (respectively OR 0.92, CI 95% 0.86-0.98, P=0.01 and OR 1.057, CI 95% 1.026-1.089, P<0.001).CONCLUSIONS: The QRS Index tightly correlated with CRT response. Only LVEF and QRS Index were independently associated with echocardiographic response to CRT.
No takes yet. Share an insight, caveat, or question.
Mugnai et al. (2023) conducted an observational in Heart failure requiring cardiac resynchronization therapy (n=326). QRS Index was evaluated on Echocardiographic response to CRT (OR 1.057, 95% CI 1.026-1.089, p=<0.001). Higher QRS Index was independently associated with an increased likelihood of echocardiographic response to cardiac resynchronization therapy (OR 1.057; 95% CI 1.026-1.089; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: