Key result
Intact ventriculo-atrial conduction linked to ~75% rate of inducible pacemaker-mediated tachycardias during ventricular extrastimulation.
Why the study?
Factors influencing initiation and perpetuation of pacemaker-mediated tachycardias (PMTs) in patients with AV universal (DDD) pulse generators were not fully understood.
Does programmed single ventricular extrastimulation initiate pacemaker-mediated tachycardias in patients with symptomatic conduction disorders and a DDD pulse generator?
Observational (n=22)
Does programmed single ventricular extrastimulation initiate pacemaker-mediated tachycardias in patients with symptomatic conduction disorders and a DDD pulse generator?
Initiation of pacemaker-mediated tachycardias in DDD pacemakers depends on retrograde VA conduction and programmable parameters, highlighting the need for device refinement.
Answers are grounded in this paper and cite their sources.
VA conduction may facilitate PMT initiation by ventricular extrastimuli; leaves open whether VA testing should guide device programming.
To evaluate factors playing a role in initiation and perpetuation of pacemaker-mediated tachycardias (PMTs), 22 consecutive patients with symptomatic conduction disorders were studied after implantation of an AV universal (DDD) pulse generator (Cordis 233D). Patients were divided into two groups, depending upon the presence or absence of ventriculo-atrial (VA) conduction during electrophysiological study (EPS) performed before pacemaker implantation. PMTs could be initiated in six of eight patients of Group I and in none of 14 patients of Group II. Initiation and perpetuation of PMTs during DDD pacing were dependent upon the capacity of the patient to conduct ventricular premature beats (VPBs) and subsequent paced ventricular beats retrogradely to the atria, and upon three programmable parameters of the pulse generator (AV delay period, upper rate limit, tachycardia response). Programmed single ventricular extrastimulation demonstrated that: (1) merely the presence of VA conduction during EPS, although necessary, was not sufficient to induce PMTs after DDD pacemaker implantation; (2) VPBs introduced late rather than early in the cardiac cycle initiated PMTs in a different way; (3) the initiation of PMTs could be prevented during study by adjusting the programmable parameters (AV delay period, upper rate limit, tachycardia response); (4) one of the two available tachycardia responses of the pulse generator (gradual fall-back response) was able to terminate and initiate PMTs consistently. These observations helped in understanding the responses of the Cordis 233D pulse generator to ventricular premature beats. They indicate that additional refinement of the pulse generator is necessary to solve the problem of PMT.
No takes yet. Share an insight, caveat, or question.
Mechelen et al. (1984) conducted an observational in Symptomatic conduction disorders (n=22). Presence of ventriculo-atrial (VA) conduction vs. Absence of ventriculo-atrial (VA) conduction was evaluated on Initiation of pacemaker-mediated tachycardias (PMTs). Pacemaker-mediated tachycardias were initiated by programmed ventricular extrastimuli in 75% (6/8) of patients with ventriculo-atrial conduction versus 0% (0/14) of those without it.
Synapse has enriched 10 related papers. Consider them for comparative context: