Electron irradiation of 100% internal quantum efficiency silicon photodiodes having a thin (60 /spl Aring/) SiO/sub 2/ dead layer results in measured responsivities ranging from 0.056 A/W at an incident electron energy E/sub 0/=0.2 keV to 0.24 A/W at E/sub 0/=40 keV. By comparing the data to a Monte Carlo simulation of electron interactions with the photodiode over an energy range of 1-40 keV, we derive an average electron-hole pair creation energy of 3.71 eV, in close agreement with other studies. Analysis of electron energy lost to processes that do not contribute to electron-hole pair creation shows that the energy lost in the SiO/sub 2/ dead layer is dominant for E/sub 0/1.5 keV. At E/sub 0/=300 eV, the Monte Carlo simulation results show that the electron projected range is significantly less than the dead layer thickness even though the measured response is 0.082 A/W, indicating that electron-hole pairs generated in the oxide dead layer are collected by the junction.
No takes yet. Share an insight, caveat, or question.
III et al. (1997) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: