Oxide scales formed on Fe-Cr alloys were characterized by electrochemical resistance measurements and microstructure observation.Fe-Cr alloy samples were exposed to air on one side and fuel gas ͑dilute CH 4 -H 2 O with N 2 ͒ on the other side under current flow ͑0.3 Acm -2 ͒ ͑dual atmospheres and current flow͒.The alloys were connected with Pt-mesh cathode and Ni-mesh anode at 1073 K.The interface resistance changes at the Ni-mesh/Fe-Cr alloy interfaces were monitored as a function of time, which increased with time in a parabolic relationship.The observed interface resistance after 800 h operation was less than 0.015 ⍀ cm 2 at 1073 K.The oxide scale phases formed were Cr-Mn-Fe spinel, Cr 2 O 3 , and SiO 2 layer from surface to inner alloy, which is almost the same with the oxide scales formed in a single atmosphere.No significant effects of dual atmosphere and current flow was observed in the formed oxide scale phases of both anode and cathode side on Fe-Cr alloys.Around the glass-sealing/alloy contact interfaces, a thick oxide scale was observed on the alloy.The reaction of glass components with alloy can affect the stability of oxide scales and alloys in the long-term operation.
No takes yet. Share an insight, caveat, or question.
Horita et al. (2006) studied this question.