Key result
Overexpanding an undersized transcatheter heart valve showed no difference in mortality, stroke, mean gradient, or significant paravalvular leak compared to conventional sizing.
Why the study?
Approximately 20%-40% of patients undergoing TAVR with balloon-expandable THV have borderline aortic annulus size, and the comparative outcomes of overexpanding versus conventional sizing strategies are unclear.
Does overexpanding an undersized transcatheter heart valve improve outcomes compared to conventional sizing in patients with borderline aortic annulus undergoing TAVR?
Meta-Analysis
Does overexpanding an undersized transcatheter heart valve improve outcomes compared to conventional sizing in patients with borderline aortic annulus undergoing TAVR?
In patients with borderline aortic annulus undergoing TAVR, overexpanding an undersized valve appears to have similar outcomes to conventional sizing, with a potential reduction in pacemaker requirements.
Comparable safety supports overexpansion of undersized THV in borderline annuli; extends meta-analytic evidence for individualized TAVR sizing.
Approximately 20%-40% of patients that present for transcatheter aortic valve replacement with a balloon-expandable transcatheter heart valve (THV) fall into a borderline aortic annulus size (BAAS). There are potential benefits to overexpanding an undersized THV (OE-THV) in such cases that include reduced electrical disturbances and annular injury at the expense of increased paravalvular leak (PVL). We conducted a meta-analysis of data comparing conventional-sized versus OE-THV strategy for BAAS and reviewed the literature for balloon-expandable-THV in such cases. 9 nonrandomized studies that compared a conventional strategy to OE-THV in patients with BAAS were included in our study. Our findings suggest that there is no difference in mortality, stroke, mean gradient, or significant PVL. There was a trend towards fewer pacemakers in patients receiving an OE-THV. Borderline aortic annulus measurements are common in patients undergoing transcatheter aortic valve replacement and there appears to be equipoise between conventional sizing versus OE-THV. Future detailed studies are required to evaluate short- and long-term outcomes among strategies.
No takes yet. Share an insight, caveat, or question.
Mustafa et al. (2025) conducted a meta-analysis in Borderline aortic annulus size undergoing transcatheter aortic valve replacement. Overexpanding an undersized transcatheter heart valve (OE-THV) vs. Conventional-sized transcatheter heart valve strategy was evaluated on Mortality, stroke, mean gradient, or significant paravalvular leak. Overexpanding an undersized transcatheter heart valve showed no difference in mortality, stroke, mean gradient, or significant paravalvular leak compared to conventional sizing.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: