Key result
GPU-accelerated inversion speeds cardiac conductivity mapping up to ~60-fold over CPUs while maintaining noise tolerance.
Why the study?
Accurate cardiac bidomain conductivity values are essential for realistic simulation, and an inversion method to retrieve these from potential measurements requires computational acceleration for sensitivity studies.
Exploiting GPUs for an inversion method to retrieve cardiac conductivities significantly accelerates execution time by up to 60-fold compared to CPUs.
May support efficient inverse modeling in cardiac research; leaves open clinical validation and adoption.
Accurate cardiac bidomain conductivity values are essential for realistic simulation of various cardiac electrophysiological phenomena. A method was previously developed that can determine the conductivities from measurements of potential on a multi-electrode array placed on the surface of the heart. These conductivities, as well as a value for fibre rotation, are determined using a mathematical model and a two-pass process that is based on Tikhonov regularisation. Using simulated potentials, to which noise is added, the inversion method was recently shown to retrieve the intracellular conductivities accurately with up to 15% noise and the extracellular conductivities extremely accurately even with 20% noise. Recent work investigated the sensitivity of the method to the choice of the regularisation parameters. Such a study only became possible due to modifications that were made to the C++ code so that it could run on graphical processing units (GPUs) on the CUDA platform. As the method required the solution of a large number of matrix equations, the highly parallel nature of GPUs was exploited to accelerate execution of the code. Reorganisation of the code and more efficient memory management techniques allowed the data to completely fit in the GPU memory. Comparison between the execution time on the GPU versus the original CPU code shows a speedup of up to 60 times. In the future, the speedup could be further increased with greater use of shared memory, which has a much lower latency (access time) than global memory. References Clayton, R. H., Bernus, O., Cherry, E. M., Dierckx, H., Fenton, F. H., Mirabella, L., Panfilov, A. V., Sachse, F. B., Seemann, G., and Zhang, H. Models of cardiac tissue electrophysiology: Progress, challenges and open questions. Progress in Biophysics and Molecular Biology, 104(1–3):22–48, 2011. doi:10.1016/j.pbiomolbio.2010.05.008 Arthur, R. M. and Geselowitz, D. B. Effect of inhomogeneities on the apparent location and magnitude of a cardiac current dipole source. IEEE Transactions on Biomedical Engineering, 17:141–146, 1970. doi:10.1109/TBME.1970.4502713 Clerc, L. Directional differences of impulse spread in trabecular muscle from mammalian heart. Journal of Physiology, 255:335–346, 1976. http://jp.physoc.org/content/255/2/335 Roberts, D. E., Hersh, L. T., and Scher, A. M. Influence of cardiac fiber orientation on wavefront voltage, conduction velocity and tissue resistivity in the dog. Circ. Res., 44:701–712, 1979. doi:10.1161/01.RES.44.5.701 Roberts, D. E. and Scher, A. M. Effects of tissue anisotropy on extracellular potential fields in canine myocardium in situ. Circ. Res., 50:342–351, 1982. doi:10.1161/01.RES.50.3.342 Hooks, D. A. Myocardial segment-specific model generation for simulating the electrical action of the heart. BioMedical Engineering OnLine, 6(1):21–21, 2007. doi:10.1186/1475-925X-6-21 MacLachlan, M. C., Sundnes, J., and Lines, G. T. Simulation of ST segment changes during subendocardial ischemia using a realistic 3-D cardiac geometry. IEEE Transactions on Biomedical Engineering, 52(5):799–807, 2005. doi:10.1109/TBME.2005.844270 Roth, B. J. Electrical conductivity values used with the bidomain model of cardiac tissue. IEEE Transactions on Biomedical Engineering, 44(4):326–328, April 1997. doi:10.1109/10.563303 Johnston, P. R. and Kilpatrick, D. The effect of conductivity values on ST segment shift in subendocardial ischaemia. IEEE Transactions on Biomedical Engineering, 50(2):150–158, February 2003. doi:10.1109/TBME.2002.807660 Johnston, P. R. Cardiac conductivity values–-a challenge for experimentalists? Noninvasive Functional Source Imaging of the Brain and Heart and 2011 8th International Conference on Bioelectromagnetism (NFSI and ICBEM), pages 39–43, 13-16 May 2011. doi:10.1109/NFSI.2011.5936816 Hooks, D. A. and Trew, M. L. Construction and validation of a plunge electrode array for three-dimensional determination of conductivity in the heart. IEEE Transactions on Biomedical Engineering, 55(2):626–635, 2008. doi:10.1109/TBME.2007.903705 Trew, M. L., Caldwell, B. J., Gamage, T. P. B., Sands, G. B., and Smaill, B. H. Experiment-specific models of ventricular electrical activation: Construction and application. In 30th Annual International IEEE EMBS Conference, pages 137–140, 2008. doi:10.1109/IEMBS.2008.4649109 Caldwell, B. J., Trew, M. L., Sands, G. B., Hooks, D. A., LeGrice, I. J., and Smaill, B. H. Three distinct directions of intramural activation reveal nonuniform side–to–side electrical coupling of ventricular myocytes. Circulation: Arrhythmia and Electropysiology, 2:433–440, 2009. doi:10.1161/CIRCEP.108.830133 Pollard, A. E., Ellis, C. D., and Smith, W. M. Linear electrode arrays for stimulation and recording within cardiac tissue space constants. IEEE Transactions on Biomedical Engineering, 55(4):1408–1414, 2008. doi:10.1109/TBME.2007.912401 Pollard, A. E. and Barr, R. C. A biophysical model for cardiac microimpedance measurements. American Journal of Physiology-Heart and Circulatory Physiology, 298:H1699–H1709, 2010. doi:10.1152/ajpheart.01131.2009 Johnston, B. M. Design of a multi–electrode array to measure cardiac conductivities. ANZIAM Journal, 54:C271–C290, 2013. http://journal.austms.org.au/ojs/index.php/ANZIAMJ/article/viewFile/6278/1694 Johnston, B. M. and Johnston, P. R. A multi-electrode array and inversion technique for retrieving six conductivities from heart potential measurements. Medical and Biological Engineering and Computing, 51(12):1295–1303, 2013. doi:10.1007/s11517-013-1101-2 Johnston, B. M. Using a sensitivity study to facilitate the design of a multi–electrode array to measure six cardiac conductivity values Mathematical Biosciences, 244:40–46, 2013. doi:10.1016/j.mbs.2013.04.003 Plonsey, R. and Barr, R. The four-electrode resistivity technique as applied to cardiac muscle. IEEE Transactions on Biomedical Engineering, 29(7):541–546, 1982. doi:10.1109/TBME.1982.324927 Johnston, B. M., Johnston, P. R., and Kilpatrick, D. A new approach to the determinination of cardiac potential distributions: Application to the analysis of electrode configurations. Mathematical Biosciences, 202(2):288–309, 2006. doi:10.1016/j.mbs.2006.04.004 Johnston, B. M., Johnston, P. R., and Kilpatrick, D. Analysis of electrode configurations for measuring cardiac tissue conductivities and fibre rotation. Annals of Biomedical Engineering, 34(6):986–996, June 2006. doi:10.1007/s10439-006-9098-4 Kuntsevich, A. and Kappel, F. SolvOpt: The solver for Local Nonlinear Optimisation Problems, version 1.1 in C. Technical Report, Institute for Mathematics: Karl–Franzens University of Graz, 1997. http://uni-graz.at/imawww/kuntsevich/solvopt/ps/manual.pdf
No takes yet. Share an insight, caveat, or question.
Johnston et al. (2014) studied Cardiac electrophysiology (simulation). GPU parallelization of inversion method vs. CPU execution was evaluated on Execution time speedup and conductivity retrieval accuracy. Running the inversion method on GPUs achieved a speedup of up to 60 times compared to CPUs, allowing accurate retrieval of extracellular cardiac conductivities even with 20% added noise.