Answers are grounded in this paper and cite their sources.
Background/Objectives: Retinal fundus photography is the most widely available means of screening for sight-threatening disease, but it is difficult to read: several conditions leave overlapping signs on the same photograph, the features that separate them are often subtle and confined to small regions of the retina, and a single image carries no systemic context, so an automated reader must resolve categories on which experienced clinicians themselves agree only moderately. Methods: We compared five deep learning architectures—EfficientNet-B3, DenseNet-121, ViT-Base/16, Inception-V3, and RETFound ViT-Large—for simultaneous seven-class retinal disease classification on a multi-source fundus image benchmark, in a retrospective computational study using stratified five-fold cross-validation. We pooled 11,223 patient-eye fundus images from three publicly available, de-identified datasets (ODIR-5K, RFMiD, and APTOS 2019) spanning age-related macular degeneration (AMD), cataract, diabetic retinopathy (DR), glaucoma, hypertensive retinopathy, pathological myopia, and normal fundus; the cohort was markedly class-imbalanced (DR, 62.5%; normal, 25.6%; each remaining class < 3%), and no new patient data were collected. Images were deduplicated by MD5 hash and split at the patient level to eliminate data leakage, with a fixed 15% held-out test set and five stratified cross-validation folds; training images received Ben Graham illumination normalization and class-balancing augmentation, while validation and test images were unaugmented. Three ImageNet-pretrained CNNs (EfficientNet-B3, DenseNet-121, Inception-V3), ViT-Base/16, and RETFound ViT-Large (pretrained on 1.6 million retinal photographs via masked autoencoding) were trained; the primary outcome was the five-fold mean weighted-averaged F1 score, pairwise comparisons used paired t-tests on fold-level F1 (df= 4), and Grad-CAM was applied for explainability. Results: EfficientNet-B3 achieved the highest five-fold mean accuracy (95.53%; weighted-F1, 0.9507) and significantly outperformed RETFound ViT-Large (ΔF1=+0.0255; t=9.70; p<0.001), ViT-Base/16 (ΔF1=+0.0075; t=9.20; p<0.001), and Inception-V3 (ΔF1=+0.0103; t=8.38; p<0.001), while performing comparably to DenseNet-121 (t=2.24; p=0.089); Grad-CAM showed clinically plausible activation localization for the CNN architectures. Conclusions: A compact, resource-efficient CNN thus matched or exceeded a substantially larger retinal foundation model and Vision Transformers, indicating that larger domain-specific foundation models are not inherently superior for heterogeneous retinal screening; because such compact models run on commodity hardware, they may offer more practical screening solutions for community, rural, and resource-limited settings where ophthalmologist coverage is scarcest. External validity across imaging sources and populations remains unproven, underscoring that prospective, multicenter validation must precede clinical deployment. A provenance audit of this pooled cohort subsequently found it confounded. The audit identified five failure modes, three of them decisive: image width alone reproduced the diabetic retinopathy label at 99.98% accuracy using no retinal pixels, source and label were almost perfectly dependent with a Cramér’s V of 0.9996, and diabetic retinopathy recall was exactly 1.0000 for all five architectures. The cohort was rebuilt from a single source with per-eye labels, and nine architectures were retrained under one protocol with external validation. The corrected headline is a macro-AUC of 0.930 internally and 0.978 externally, with a macro-F1 of 0.686. No architecture is declared superior, and the pooled-cohort conclusion does not stand.
No takes yet. Share an insight, caveat, or question.
Alutaibi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: