This is the authors' abstract. We don't add key points for this paper.
The paper analyzes the methods of temperature measurements of cooling the high-temperature bodies in liquids. Experimental studies on cylindrical samples with different embedding of thermocouples have been carried out in three liquids. It is shown that even in the case of cooling in saturated liquids, external thermocouples, whose electrodes play the role of cooling fins, distort the measured temperatures significantly. Using external thermocouples, it is impossible to record correctly the rate of hot body cooling in liquid and the temperature of transition of cooling to an intensive regime. Using only a central thermocouple is permissible at low Biot numbers. However, even in this case, with intensive cooling, the difference between the temperatures of the center and the surface can reach several tens of degrees. With a decrease in the thermal conductivity of a sample and an increase in its linear dimensions, the temperature gradient increases (especially at intense cooling), and the correct physical interpretation of the process becomes impossible.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Zabirov et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: