Why the study?
A mechanistic failure mode involving post-MI scar remains untreated in ICD patients with narrow QRS, CRT non-responders, and functional MR patients, representing a treatment gap in ischaemic heart failure.
Does left ventricular partitioning with the Parachute device improve mortality and functional outcomes in patients with symptomatic ischemic heart failure and LVEF <40%?
Meta-Analysis (n=134)
Does left ventricular partitioning with the Parachute device improve mortality and functional outcomes in patients with symptomatic ischemic heart failure and LVEF <40%?
A pooled analysis of early clinical trials suggests that left ventricular partitioning with the Parachute device is associated with a 12.9% cumulative mortality rate at two years in patients with symptomatic ischemic heart failure.
ICD patients with narrow QRS, CRT non-responders, and functional MR patients all have one mechanistic failure mode that is left untreated - the scar left behind following an MI. ICDs, CRTs, and MitraClip implantation are all well-proven therapies, but the Parachute device may address the mechanistic void that remains after each of these therapies has been used and may further improve patients' outcomes. A pooled analysis of 134 subjects was conducted using the first three clinical trials which included subjects with symptomatic ischaemic HF with LV wall motion abnormalities secondary to MI, and an LV ejection fraction less than 40%. The two-year cumulative mortality rate was 12.9%, with 8.7% in the first year and an increment of 4.2% in the second, which is a 53% reduction as compared to the first year. There is a significant proportion of patients with ischaemic heart failure being excluded from cardiac rhythm management (CRT, etc.), leaving a large treatment gap until mechanical support devices (LVAD) or heart transplantation in progressive heart failure are indicated. Along with other heart failure devices, Parachute may be a useful treatment modality, addressing a mechanistic void in the treatment of this disease. Current data support improvements in haemodynamics, functional capacity, six-minute walk distance, quality of life and a promising decline in mortality two years after Parachute implantation.
No takes yet. Share an insight, caveat, or question.
Ulrich Schäfer (2016) conducted a meta-analysis in Symptomatic ischaemic heart failure (n=134). Parachute device was evaluated on Two-year cumulative mortality rate.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: