Key result
Mitral valve replacement for calcified annulus achieves 0% hospital mortality with no superior surgical technique.
Why the study?
Standard suture techniques for mitral annulus calcification may cause fracture and paravalvular leak, necessitating evaluation of alternative surgical methods.
What are the outcomes of different surgical techniques for mitral valve replacement in patients with a calcified mitral annulus?
Observational (n=17)
What are the outcomes of different surgical techniques for mitral valve replacement in patients with a calcified mitral annulus?
Various surgical techniques for mitral valve replacement in patients with calcified mitral annulus can be performed safely with good functional outcomes, with no single technique proving clearly superior.
Answers are grounded in this paper and cite their sources.
Alternative mitral annulus techniques may limit paravalvular leak in calcification; leaves open optimal method for larger prospective validation.
Mitral annulus calcification is most often associated with myxomatous degeneration of the mitral valve. It is characterized by a horseshoe-shaped area of mitral annulus calcification that extends into the ventricular cavity to varying degrees. Standard suture techniques may be associated with fracture of the calcification and subsequent paravalvular leak. Seventeen patients aged 54 to 85 (mean 68.1) had mitral valve replacement using four techniques: suture through calcified annulus (3); decalcification (6); onlay patch (5); and drill technique (3). There were no hospital deaths, and one 81-year-old patient with associated coronary artery disease and ascending aortic calcification succumbed to a cerebrovascular accident three months postoperatively. The remaining patients are living and active with functional improvement. Follow-up has ranged from seven months to seven years with a mean of 4.0 years. One patient has hemodynamically insignificant mitral regurgitation after use of an onlay patch technique. No one technique could be singled out as clearly advantageous over the others from this series of patients.
No takes yet. Share an insight, caveat, or question.
Mills et al. (1986) conducted an observational in Mitral annulus calcification (n=17). Mitral valve replacement techniques (suture through calcified annulus, decalcification, onlay patch, drill technique) was evaluated on Hospital deaths and functional improvement. Mitral valve replacement using four techniques for calcified mitral annulus in 17 patients resulted in 0 hospital deaths and functional improvement, with no single technique clearly advantageous.
Synapse has enriched 10 related papers. Consider them for comparative context: