Key result
Intraoperative TEE identifies Eustachian valve-mediated cannula obstruction during cardiopulmonary bypass.
Why the study?
There are few reports on the use of transesophageal echocardiography for troubleshooting poor venous return during cardiopulmonary bypass.
Case Report (n=1)
Intraoperative TEE is a valuable tool for troubleshooting and diagnosing mechanical complications during cardiopulmonary bypass, such as venous cannula obstruction by a Eustachian valve.
TEE may aid CPB venous return troubleshooting; hypothesis-generating case report requiring prospective validation before practice change.
Transesophageal echocardiography (TEE) is now widely accepted as being useful in the management of patients undergoing cardiac surgery. There are also reports of using TEE to assist with placement of cannula for cardiopulmonary bypass (CPB) (1–3). However, there are few reports of the use of TEE for troubleshooting problems during CPB. We present a case in which intraoperative TEE assisted in the diagnosis of poor venous return during CPB. A 64-year-old man presented for redo-sternotomy and heart transplantation. CPB was instituted after cannulation of the ascending aorta and the left femoral vein. At the time of femoral venous cannula placement, TEE was used to confirm positioning of the tip of the venous cannula at the junction of the inferior vena cava (IVC) and right atrium. After initiation of CPB, venous return flow was noted to be low and his cardiac index was <2 L · min−1· m−2. Low venous return to the CPB circuit may be related to low blood volume, air in the venous return line, inappropriate cannula placement, or obstruction of the cannula. Vacuum was applied to the circuit without improvement in venous return. At this time TEE examination revealed intermittent obstruction of the venous cannula inflow by a large, redundant Eustachian valve (Figs. 1 and 2 and please see video loop available at www.anesthesia-analgesia.org). After withdrawal of the venous cannula by a few centimeters, venous return promptly improved and the cardiac index increased to 2.3 L · min−1· m−2.Figure 1.: Transesophageal echocardiography bicaval image demonstrating the venous cannula at the junction of the right atrium and inferior vena cava. The Eustachian valve is also noted.Figure 2.: Similar transesophageal echocardiography image as for Figure 1 demonstrating obstruction of the venous cannula by the Eustachian valve (arrow) after initiation of cardiopulmonary bypass.TEE may be used for guiding CPB IVC cannula placement during direct insertion via a median sternotomy. Avoiding malposition of the venous cannula in the hepatic vein by TEE examination has been described (2). Our case demonstrates that TEE examination is also important for assisting in positioning the IVC cannula when placed via the femoral vein. In this situation, TEE first confirms placement of the guidewire in the atrium and then the correct positioning of the subsequently placed venous cannula at the right atrium and IVC junction. In our case, the venous cannula appeared to be properly positioned on TEE examination, and obstruction to venous inflow was not evident until initiation of CPB. The Eustachian valve is a vestigial portion of the IVC which functions during fetal life to direct IVC blood flow across the foramen ovale. Occasionally, similar vestigial structures are fenestrated and more extensive (Chiari network). Recognition of obstruction of the venous cannula by the residual Eustachian valve was facilitated by the use of intraoperative TEE, including during initiation of CPB. ACKNOWLEDGMENTS The author thanks Dr. Peter Bailey for assistance in preparing the manuscript.
No takes yet. Share an insight, caveat, or question.
Ellen D. Iannoli (2007) conducted a case report in Poor venous return during cardiopulmonary bypass (n=1). Transesophageal echocardiography (TEE) was evaluated on Diagnosis of the cause of poor venous return. Intraoperative transesophageal echocardiography successfully identified intermittent obstruction of the venous cannula inflow by a large Eustachian valve during cardiopulmonary bypass.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: