This study investigates the impingement cooling characteristics of racetrack-shaped holes under complex crossflow conditions using numerical simulation and compares them with traditional cylindrical holes. The flow and heat transfer characteristics of both hole geometries are systematically analyzed and compared under varying crossflow intensities. The internal crossflow induces uneven momentum distribution within the holes, leading to flow separation at the orifice inlet. Under identical crossflow conditions, racetrack holes exhibit a smaller relative separation area, resulting in superior flow resistance characteristics. This is reflected in their higher discharge coefficient compared to cylindrical holes when internal crossflow is present. In terms of heat transfer, the area-averaged Nu number of racetrack holes increases monotonically with internal crossflow intensity, whereas cylindrical holes show a break in this trend under extreme crossflow conditions. Racetrack holes achieve a 3.6%–14% higher area-averaged Nu number than cylindrical holes. The combined optimization of flow resistance and heat transfer enhancement results in racetrack holes consistently achieving an overall thermal efficiency greater than 1, indicating superior flow resistance-heat transfer conversion efficiency. In contrast, cylindrical holes always exhibit an overall thermal efficiency below 1.