Answers are grounded in this paper and cite their sources.
Critical flux ( J crit ), the threshold flux above which fouling accelerates, is central to fouling mitigation. However, experimentally derived J crit values are not readily transferable from one water chemistry to another and are inherently sensitive to design protocols. This makes comprehensive mapping of operating windows not only difficult to generalize but also time-consuming and costly. This work reports a parsimonious surrogate framework which uses routine aqueous chemistry parameters such as pH, total ionic strength ( I total ) and water hardness (Ca 2+ ) as the predominant drivers for predicting J crit for oil-in-water emulsion filtration. This enables rapid a priori screening and identification of the optimal combination of the aqueous chemistry parameters that maximizes J crit and delays the onset of early fouling. A novel kaolin-based ceramic membrane coated with graphene oxide (GO) and modified by in-situ CaCO₃-templated H₂O₂ etching was used to validate the study. Several candidate surrogate models governed by 4 to 7 parameters were evaluated using calibration performance, holdout validation, leave-one-out cross-validation, and repeated randomized calibration–holdout splits. The 5-parameter surrogate model was selected because it favored both superior predictive accuracy and minimal parameterization. Validation on the holdout chemistries yielded RMSE of 0.094 and R 2 of 0.925 on natural log-transformed J crit , with all holdout observations contained within the 95% prediction intervals.
No takes yet. Share an insight, caveat, or question.
Avornyo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: