Key result
RCA guidewire with balloon predilatation effectively guides valve-in-valve TTVR in radiolucent bioprostheses.
Why the study?
Transcatheter valve-in-valve implantation in the tricuspid position is challenging due to radiolucent bioprosthetic valves complicating accurate valve positioning and deployment.
Case Report (n=3)
No
May aid tricuspid ViV in radiolucent valves; hypothesis-generating and requires prospective validation before adoption.
AIMS: Transcatheter implantation of valved stents (Melody and Edwards valves) for replacement of the pulmonary valve is currently an established procedure. We reviewed our experience on implantation of such valves in the tricuspid valve position. METHODS AND RESULTS: Transcatheter valve implantation in the tricuspid position was attempted in five patients. Four patients had predominantly tricuspid valve regurgitation, two of whom also had tricuspid valve stenosis. All patients had severely symptomatic right heart failure. Patient median age and weight were 12 years and 50 kg (range six-43 years and 13-68 kg, respectively). All patients had a bioprosthetic valve already in place. The mean gradient across the tricuspid valve decreased from 12 to 3 mmHg after the procedure. Median procedure time and fluoroscopy time were 100 and 39 min (range 60-180 and 30-57 min, respectively). The patients' functional class improved from NYHA Class III to II in three and from Class III to I in two patients during a follow-up period of 15-22 months. CONCLUSIONS: Transcatheter replacement of malfunctioning bioprosthetic valves in the tricuspid position using valved stents is an attractive alternative to repeat surgery in high-risk or multi-operated patients. Longer follow-up and a larger number of patients are required to establish the long-term benefit of the procedure and freedom from reinterventions.
No takes yet. Share an insight, caveat, or question.
Tzifa et al. (2014) conducted a case report in Degenerated tricuspid bioprosthesis (tricuspid valve dysfunction) (n=3). Transcatheter valve-in-valve implantation using RCA guidewire and balloon predilatation was evaluated on Procedural success (accurate valve positioning and deployment without residual regurgitation). The use of a right coronary artery guidewire combined with balloon predilatation provided an effective anatomical marker for successful transcatheter valve-in-valve implantation in patients with radiolucent tricuspid bioprostheses.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: