Key result
RV zone 8/9 leadless pacing is linked to ~12% shorter aortic pre-ejection period vs non-8/9 zones.
Why the study?
Optimization of leadless pacemaker placement and its impact on cardiac electromechanical synchronization and tricuspid regurgitation were investigated.
Does leadless pacemaker implantation in the right ventricular 8/9 zone improve cardiac electromechanical synchronization and prevent tricuspid regurgitation compared to non-8/9 zones?
Cohort (n=53)
Yes
Does leadless pacemaker implantation in the right ventricular 8/9 zone improve cardiac electromechanical synchronization and prevent tricuspid regurgitation compared to non-8/9 zones?
Targeting the right ventricular 8/9 zone for leadless pacemaker implantation significantly improves cardiac electromechanical synchronization and may mitigate the worsening of tricuspid regurgitation compared to other implantation sites.
Answers are grounded in this paper and cite their sources.
May favor RV 8/9 zone for leadless pacemakers to enhance synchronization; leaves open confirmation in larger randomized trials.
BACKGROUND: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation. RESULTS: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging. Intraoperative and 1-month post-operative echocardiography was performed to assess cardiac electromechanical synchronization and tricuspid regurgitation; parameters of interest included interventricular mechanical delay (IVMD), pre-ejection period of the aorta (L-PEI), and septal-to-posterior wall motion delay (SPWMD). Pacing thresholds, sensing, and impedance exhibited no significant differences between the 8/9 zone and other sites (P > 0.05). In contrast, the 8/9 zone group manifested a significant reduction in L-PEI (128.24 ± 12.27 vs. 146.50 ± 18.17 ms, P < 0.001), IVMD (17.92 ± 8.47 vs. 28.56 ± 15.16 ms, P < 0.001), and SPWMD (72.84 ± 19.57 vs. 156.56 ± 81.54 ms, P < 0.001), compared to the non-8/9 group. Post-pacing QRS duration showed no significant difference between the two groups (139.21 ± 11.36 vs. 143.83 ± 16.35 ms P = 0.310). Notably, for patients with atrial fibrillation, the 8/9 zone placement significantly reduced tricuspid regurgitation. During the 1-month follow-up, neither group reported major complications such as bleeding, cardiac tamponade, pacemaker detachment, or malignant arrhythmias. CONCLUSION: Implantation of the leadless pacemaker in the right ventricular 8/9 zone provides superior electromechanical synchronization compared to other sites.
No takes yet. Share an insight, caveat, or question.
Gao et al. (2025) conducted a cohort in Bradyarrhythmias requiring pacemaker (sick sinus syndrome, AV block, atrial fibrillation with slow ventricular rate) (n=53). Leadless pacemaker implantation in the right ventricular 8/9 zone vs. Leadless pacemaker implantation in non-8/9 zones was evaluated on Pre-ejection period of the aorta (L-PEI) (p=<0.001). Implantation of a leadless pacemaker in the right ventricular 8/9 zone improved cardiac electromechanical synchronization, including a reduced pre-ejection period of the aorta, compared to non-8/9 zones.
Synapse has enriched 10 related papers. Consider them for comparative context: