Key result
New-generation DES cuts TLR risk ~48% vs. DCB in coronary in-stent restenosis.
Why the study?
The comparative angiographic and clinical outcomes of new-generation drug-eluting stents versus drug-coated balloons in patients with coronary in-stent restenosis were unclear.
Meta-Analysis (n=913)
Yes
Relative Risk: 1.96 (95% CI 1.17–3.28)
Absolute Event Rate: 5.2% vs 10.9%
p-value: p=0.01
New-generation DES preferred over DCB for coronary ISR to reduce TLR; confirms benefit across five RCTs.
OBJECTIVE: The study sought to compare angiographic and clinical outcomes of new-generation drug-eluting stents (DES) versus drug-coated balloon (DCB) in patients with coronary in-stent restenosis (ISR). DESIGN: Meta-analysis using data from randomised trial found by searches on PubMed, the Cochrane Library, ClinicalTrials.gov and websites of major cardiovascular congresses. SETTING: Only randomised trials comparing DES with DCB were included. PARTICIPANTS: Patients with ISR in the included trials. INTERVENTIONS: New-generation DES versus DCB. OUTCOMES: The angiographic and clinical outcomes including cardiac death, all-cause death, myocardial infarction, target lesion revascularisation (TLR), target vessel revascularisation (TVR), major adverse cardiac events (MACE) and stent thrombosis were investigated. RESULTS: Five trials including 913 patients were eligible and included. Pooled analysis in angiographic results identified that new-generation DES were associated with higher acute luminal gain (-0.31 mm, 95% CI -0.42 to -0.20, P<0.001) and lower per cent diameter stenosis (risk ratio (RR): 0.28, 95% CI 0.02 to 0.55, P=0.04). DES significantly reduced the risk of TLR (RR: 1.96, 95% CI 1.17 to 3.28, P=0.01) compared with DCB; however, there was no statistical differences for MACE (RR: 1.21, 95% CI 0.67 to 2.17, P=0.53), myocardial infarction (RR: 1.16, 95% CI 0.55 to 2.48, P=0.69) and cardiac death (RR: 1.80, 95% CI 0.60 to 5.39, P=0.29). CONCLUSIONS: Interventions with new-generation DES appear to be associated with significant reduction in per cent diameter stenosis and TLR at short-term follow-up, but had similar MACE, myocardial infarction and cardiac death for patients with coronary ISR compared with DCB. Appropriately powered studies with longer term follow-up are warranted to confirm these findings.
No takes yet. Share an insight, caveat, or question.
Cai et al. (2018) conducted a meta-analysis in Coronary in-stent restenosis (n=913). New-generation drug-eluting stents vs. Drug-coated balloon was evaluated on Target lesion revascularisation (TLR) (RR 1.96, 95% CI 1.17 to 3.28, p=0.01). New-generation drug-eluting stents significantly reduced the risk of target lesion revascularization compared with drug-coated balloons (5.2% vs 10.9%, RR 1.96) in patients with coronary in-stent restenosis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: