Key result
Mitroflow linked to ~137% higher 10-year mortality compared to Perimount Magna.
Why the study?
Biological valves are the most commonly used prostheses for AVR surgery in the UK, but comparative 10-year outcomes of Perimount Magna and Mitroflow bioprostheses were not well established.
Observational (n=2,608)
No
Absolute Event Rate: 34.8% vs 14.7%
p-value: p=< .001
Mitroflow associated with higher 10-year mortality and reintervention than Perimount Magna; leaves open durability differences pending prospective validation.
OBJECTIVES: Biological valves are the most commonly used prostheses for aortic valve replacement (AVR) surgery in the UK. The aim of this retrospective observational study was to compare 10-year outcomes of Perimount Magna and Mitroflow bioprosthesis implanted in a single center. METHODS: The medical records of patients undergoing AVR in Liverpool Heart and Chest Hospital between 1999 and 2014 were examined. All data were collected retrospectively, and a propensity match analysis was performed with a ratio 3:1 to analyze 10-year outcomes. The primary outcomes were all-cause mortality rates and aortic valve reintervention rates. RESULTS: A total of 2608 patients were included; Mitroflow bioprosthesis was used in 352 patients while Perimount Magna was used in 2256 patients. Median (interquartile range [IQR]) follow-up for the entire data set was 6.95 (4.99, 9.69) years. After 10 years, the all-cause mortality rate was higher in Mitroflow cohort 34.8% vs 14.7% (P < .001). A higher rate of aortic valve reintervention was observed in the Mitroflow cohort (4.7% vs 1%, P < .001). CONCLUSIONS: There were significant differences in survival and reintervention-free survival rate between the two groups considered. The implant of the Perimount Magna valve seems to have a better short-term and long-term outcome over Mitroflow valve. Such results require larger studies to be validated.
No takes yet. Share an insight, caveat, or question.
Theologou et al. (2019) conducted an observational in Aortic valve replacement (n=2,608). Mitroflow bioprosthesis vs. Perimount Magna bioprosthesis was evaluated on All-cause mortality rates (p=< .001). Mitroflow bioprosthesis was associated with higher 10-year all-cause mortality (34.8% vs 14.7%, P<.001) and aortic valve reintervention rates (4.7% vs 1%, P<.001) compared to Perimount Magna.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: